{"id":2755,"date":"2026-08-22T09:26:12","date_gmt":"2026-08-22T09:26:12","guid":{"rendered":"https:\/\/www.bionicsscientific.com\/blogs\/?p=2755"},"modified":"2026-08-22T09:26:30","modified_gmt":"2026-08-22T09:26:30","slug":"autoclave-print-out","status":"publish","type":"post","link":"https:\/\/www.bionicsscientific.com\/blogs\/autoclave-print-out\/","title":{"rendered":"Autoclave print out: How to Read It, Why It Matters, and What Every Buyer Should Know"},"content":{"rendered":"<p><b>Quick Answer:<\/b><span style=\"font-weight: 400;\"> Autoclave Print out is the physical or digital record a sterilizer generates at the end of every cycle. It logs the chamber temperature, pressure, hold time, and cycle number, and it serves as legal proof that a sterilization cycle actually reached the parameters needed to kill microorganisms. Labs, hospitals, and biomedical waste units keep these printouts on file for audits, NABL\/NABH accreditation, and biomedical waste compliance.<\/span><\/p>\n<h2><b>Why the Autoclave Print Out Exists in the First Place<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An autoclave doesn&#8217;t just &#8220;run a cycle&#8221;\u2014it has to prove it ran the cycle correctly. That proof is the printout. Every time a batch of instruments, culture media, glassware, or biomedical waste goes through a sterilization cycle, the machine&#8217;s controller tracks three things continuously: temperature inside the chamber, pressure of the steam, and the duration for which both were held steady. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">At the end of the cycle, this data is pushed to a built-in thermal printer or exported to a connected system, giving the operator a strip of paper (or a digital PDF) that can be pinned to a batch record.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For a microbiology lab, this isn&#8217;t paperwork for its own sake. If an inspector, auditor, or hospital infection-control officer ever asks, &#8220;How do you know this batch was sterile?&#8221; the printout is the answer. It replaces guesswork with a timestamped, parameter-by-parameter record.<\/span><\/p>\n<h2><b>What Actually Appears on a Standard Printout<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A well-designed autoclave printout is not just a temperature number. A complete report typically includes:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cycle number and date\/time stamp<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Program selected (e.g., 121\u00b0C liquid cycle, 134\u00b0C instrument cycle)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Chamber temperature curve through pre-vacuum, sterilization, and exhaust phases<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pressure readings (in bar or psi) corresponding to each phase<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Sterilization hold time (how long the set temperature was actually maintained, not just reached)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Total cycle duration<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pass\/fail or &#8220;cycle complete&#8221; status<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Operator ID or batch reference, where the controller supports it<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">This is exactly the kind of granularity that separates an entry-level autoclave from an industrial one. A basic pressure cooker-style unit might give you a needle on a dial and nothing on paper. An industrial-grade autoclave\u2014the kind used in pharma QC labs, CROs, and central sterile supply departments\u2014is expected to generate this printout automatically, without the operator having to manually log numbers off a gauge.<\/span><\/p>\n<h2><b>Vertical vs. Horizontal Autoclave: Does the Printout Differ?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The underlying logic is the same whether you&#8217;re running a <\/span><a href=\"https:\/\/www.bionicsscientific.com\/autoclave-sterilizer\/vertical-type-autoclave-steam-sterilizer.php\"><span style=\"font-weight: 400;\">vertical autoclave<\/span><\/a><span style=\"font-weight: 400;\"> or a horizontal autoclave\u2014both are producing a time\u2013temperature\u2013pressure record. The practical difference is in scale and workflow. A vertical autoclave is generally used where floor space is limited and batch sizes are moderate\u2014smaller labs, colleges, and diagnostic centers. A horizontal autoclave is built for higher throughput: bulk glassware, larger biomedical waste loads, and hospital CSSD operations, where a horizontal loading trolley and larger chamber volume matter. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Buyers comparing a vertical autoclave diagram against a <\/span><a href=\"https:\/\/www.bionicsscientific.com\/autoclave-sterilizer\/horizontal-type-autoclave-steam-sterilizer.php\"><span style=\"font-weight: 400;\">horizontal autoclave<\/span><\/a><span style=\"font-weight: 400;\"> diagram will notice the horizontal design usually integrates a front-loading door and rail system, while the vertical design uses a top-loading chamber\u2014but the printer module and the report format are typically identical across both, since compliance requirements don&#8217;t change with chamber orientation.<\/span><\/p>\n<h2><b>Specification Table<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Parameter<\/b><\/td>\n<td><b>Vertical Autoclave<\/b><\/td>\n<td><b>Horizontal Autoclave<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Chamber Loading<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Top-loading<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Front-loading (rail\/trolley)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Typical Capacity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">22 L \u2013 250 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">100 L \u2013 1000+ L<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Working Pressure<\/span><\/td>\n<td><span style=\"font-weight: 400;\">15\u201321 psi (1.05\u20131.5 bar)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">15\u201330 psi (1.05\u20132.1 bar)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Sterilization Temp.<\/span><\/td>\n<td><span style=\"font-weight: 400;\">121\u00b0C \u2013 134\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">121\u00b0C \u2013 134\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Print Out Type<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Thermal strip \/ digital PDF<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Thermal strip \/ digital PDF<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Ideal Use<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Labs, colleges, clinics<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Hospitals, CSSD, bulk waste units<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Common Drum Sizes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">8&#8243;x16&#8243;, 10&#8243;x20&#8243;, 12&#8243;x24&#8243;<\/span><\/td>\n<td><span style=\"font-weight: 400;\">16&#8243;x24&#8243;, 18&#8243;x30&#8243;, 20&#8243;x36&#8243;<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Autoclave Temperature Chart<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Sterilization Temp.<\/b><\/td>\n<td><b>Standard Hold Time<\/b><\/td>\n<td><b>Typical Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">121\u00b0C (15 psi)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">15\u201320 minutes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Liquids, culture media, general glassware<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">126\u00b0C (18 psi)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10\u201315 minutes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Dressings, surgical linen<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">134\u00b0C (30 psi)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3\u20135 minutes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Wrapped instruments, rapid turnaround loads<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">121\u00b0C (biomedical waste cycle)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">30\u201360 minutes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Hydroclaving\/autoclaving of biomedical waste, per <\/span><a href=\"https:\/\/cpcb.gov.in\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">CPCB norms<\/span><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Where the Print Out Becomes Legally Important: Biomedical Waste<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Autoclaving of biomedical waste\u2014sometimes called hydroclaving of biomedical waste when a shredding-cum-sterilization unit is used\u2014is regulated. Common Biomedical Waste Treatment Facilities (CBWTFs) and hospitals running captive autoclaves are expected to maintain an <\/span><b>autoclave register<\/b><span style=\"font-weight: 400;\">, and the daily printout is what gets pasted or logged into that register against each batch. Regulators check this register format during inspections; a missing or inconsistent printout is one of the most common compliance gaps found in biomedical waste audits.<\/span><\/p>\n<h2><b>The Autoclave Register: Where Printouts Get Filed<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An autoclave register format usually captures, batch by batch: date, cycle number, load type, operator name, temperature achieved, hold time, and a pass\/fail column\u2014with the printout either stapled alongside or referenced by cycle number. Facilities that digitize this process still keep the printout as the primary evidence; the register is simply the index.<\/span><\/p>\n<h2><b>A Less-Obvious Use Case: Mushroom Cultivation<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Autoclave for mushroom cultivation is a growing use case outside conventional lab settings. Substrate bags need to be sterilized at 121\u00b0C for a sustained hold time to eliminate competing contaminants before spawning. Here too, growers increasingly ask for a printout\u2014not for regulatory reasons, but simply to confirm the substrate batch actually reached full sterilization before it&#8217;s sealed and inoculated, since an under-sterilized batch means a wasted cycle and lost substrate cost.<\/span><\/p>\n<h2><b>What Buyers Are Actually Thinking Before They Buy<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Anyone researching an autoclave purchase is usually working through the same mental checklist, even if they don&#8217;t say it out loud:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Will this machine actually give me a printout, or will I be logging numbers by hand?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Manual logging is slower and more error-prone during audits.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Is the chamber size right for my batch volume, or will I be running extra cycles?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">What&#8217;s the autoclave HSN code for GST\/import documentation? \u2014 For laboratory sterilizers, autoclave HSN code typically falls under 8419, though buyers should confirm the exact sub-heading with their supplier for invoicing.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Can the supplier support me after installation\u2014validation, spares, and service visits?<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Does the manufacturer have a track record, or is the device a first-generation product?<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">That last point is often the deciding factor, and it&#8217;s a fair one to ask about.<\/span><\/p>\n<h2><b>Why Buyers Choose Bionics Scientific<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Bionics Scientific has been manufacturing laboratory and biomedical equipment for 35 years. In that time, the company has designed, built, and dispatched over 1,900 vertical and horizontal autoclaves to laboratories, hospitals, research institutes, and biomedical waste facilities across every region of India, as well as to buyers overseas. That volume isn&#8217;t a marketing number \u2014 it&#8217;s three and a half decades of iterating on chamber design, printer integration, gasket life, and after-sales support based on what actual labs and hospitals have asked for.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">When a buyer wants an autoclave that produces a reliable, audit-ready printout every single cycle\u2014not just on day one, but on cycle number 5,000\u2014that track record is what the decision usually comes down to.<\/span><\/p>\n<p><b>Looking for a vertical or horizontal autoclave that gives you a dependable printout every cycle? Talk to Bionics Scientific&#8217;s <\/b><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"><b>technical team<\/b><\/a><b> for the right chamber size, validation support, and pan-India delivery.<\/b><\/p>\n<h2><b>FAQs\u00a0<\/b><\/h2>\n<p><b>What is an autoclave printout?\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">An autoclave printout is a record of the temperature, pressure, and time that the process takes place in an autoclave as proof of the proper completion of the sterilization cycle.<\/span><\/p>\n<p><b>Why do laboratories need autoclave printouts?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">For the purposes of the accreditation audit, biomedical waste compliance check, and internal record keeping.<\/span><\/p>\n<p><b>What&#8217;s the difference between a vertical and horizontal autoclave diagram?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A vertical autoclave diagram shows a top-loading chamber suited to smaller labs; a horizontal autoclave diagram shows a front-loading chamber with rail\/trolley loading, suited to hospitals and bulk sterilization.<\/span><\/p>\n<p><b>What temperature should an autoclave reach for standard sterilization?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">121\u00b0C is standard for most liquids and general loads; 134\u00b0C is used for faster, wrapped-instrument cycles. See the temperature chart above for hold times.<\/span><\/p>\n<p><b>What is an autoclave register, and is it mandatory?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">It&#8217;s a logbook recording every sterilization cycle\u2014date, batch, temperature, hold time, result. Biomedical waste facilities are expected to maintain one, and it&#8217;s checked during regulatory inspections.<\/span><\/p>\n<p><b>What is the HSN code for an autoclave?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Laboratory autoclaves generally fall under HSN code 8419. Buyers would need to check with their supplier what exact HSN code needs to be used for GST invoicing.<\/span><\/p>\n<p><b>What are common autoclave drum sizes?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Vertical units commonly range from 8&#8243;x16&#8243; up to 12&#8243;x24&#8243;; horizontal units range from 16&#8243;x24&#8243; up to 20&#8243;x36&#8243; and larger, depending on chamber capacity.<\/span><\/p>\n<p><b>What&#8217;s the difference between autoclaving and hydroclaving of biomedical waste?\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Autoclaving sterilizes waste using pressurized steam alone. Hydroclaving commonly combines shredding and steam sterilization in a single unit for reducing and sterilizing waste.<\/span><\/p>\n<p><b>Can an autoclave be used for mushroom cultivation substrate?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Yes, substrate bags are commonly sterilized at 121\u00b0C for an extended hold time to eliminate contaminants before spawning.<\/span><\/p>\n<p><b>How do I choose between a vertical and horizontal autoclave for my facility?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">It comes down to batch volume and floor space: vertical units suit smaller, space-constrained labs; horizontal units suit high-throughput hospital or CBWTF operations. Bionics Scientific&#8217;s team can help match chamber size to your actual load volume.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Quick Answer: Autoclave Print out is the physical or digital record a sterilizer generates at the end of every cycle. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2756,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2755","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-autoclave"],"uagb_featured_image_src":{"full":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out.png",996,497,false],"thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out-150x150.png",150,150,true],"medium":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out-300x150.png",300,150,true],"medium_large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out-768x383.png",768,383,true],"large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out.png",996,497,false],"1536x1536":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out.png",996,497,false],"2048x2048":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out.png",996,497,false],"web-stories-poster-portrait":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out-640x497.png",640,497,true],"web-stories-publisher-logo":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out-96x96.png",96,96,true],"web-stories-thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/autoclave-print-out-150x75.png",150,75,true]},"uagb_author_info":{"display_name":"Team Bionics Scientific Technologies","author_link":"https:\/\/www.bionicsscientific.com\/blogs\/author\/bionicsadmin\/"},"uagb_comment_info":0,"uagb_excerpt":"Quick Answer: Autoclave Print out is the physical or digital record a sterilizer generates at the end of every cycle. [&hellip;]","_links":{"self":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2755","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/comments?post=2755"}],"version-history":[{"count":1,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2755\/revisions"}],"predecessor-version":[{"id":2757,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2755\/revisions\/2757"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media\/2756"}],"wp:attachment":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media?parent=2755"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/categories?post=2755"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/tags?post=2755"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}