{"id":2762,"date":"2026-08-27T07:39:15","date_gmt":"2026-08-27T07:39:15","guid":{"rendered":"https:\/\/www.bionicsscientific.com\/blogs\/?p=2762"},"modified":"2026-08-27T07:39:15","modified_gmt":"2026-08-27T07:39:15","slug":"lab-centrifuge","status":"publish","type":"post","link":"https:\/\/www.bionicsscientific.com\/blogs\/lab-centrifuge\/","title":{"rendered":"Lab Centrifuge: The Complete Guide to Lab, Blood Bank, and Pharma Applications"},"content":{"rendered":"<p><b>Quick answer:<\/b><span style=\"font-weight: 400;\"> A lab centrifuge spins samples at high speed so components separate by density and sedimentation rate\u2014denser material moves outward, and lighter material stays closer to the axis. Blood banks use them to split whole blood into red cells, plasma, and platelets. Diagnostic labs use them for urine sediment and gel cards. Pharma QC teams use them for sample prep.<\/span><a href=\"https:\/\/bionicsscientific.com\/\"> <span style=\"font-weight: 400;\">Bionics Scientific<\/span><\/a><span style=\"font-weight: 400;\"> has manufactured this equipment for over 35 years, with an installed base across India and export markets including Saudi Arabia, the UAE, Oman, Qatar, and the USA <\/span><i><span style=\"font-weight: 400;\">(detailed shipment records and client references are available on request)<\/span><\/i><span style=\"font-weight: 400;\">.<\/span><\/p>\n<h2><b>What Actually Happens Inside a Lab Centrifuge<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Spin a sample fast enough around a fixed axis, and physics does the sorting. Particles separate according to their sedimentation rate, which depends on particle density relative to the fluid, particle size, fluid viscosity, and applied force\u2014not on density alone. That&#8217;s why protocols specify a force and a duration together, not just one number.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A rotor holds the tubes or bags. Speed is measured two ways: <\/span><b>RPM<\/b><span style=\"font-weight: 400;\"> (raw rotational speed) and <\/span><b>RCF<\/b><span style=\"font-weight: 400;\">, or relative centrifugal force, expressed as x <\/span><i><span style=\"font-weight: 400;\">g<\/span><\/i><span style=\"font-weight: 400;\">. <\/span><b>RCF is what actually matters for lab protocols \u2014 not RPM.<\/b><span style=\"font-weight: 400;\"> RCF depends on both speed and rotor radius (RCF \u2248 1.118 \u00d7 10\u207b\u2075 \u00d7 r \u00d7 RPM\u00b2), so the same RPM on a small rotor and a larger one produces different forces. A spec sheet or protocol that quotes RPM alone is incomplete\u2014always verify the RCF for the rotor actually in use.<\/span><\/p>\n<h2><b>Centrifuge Uses in Laboratory Settings<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Blood component separation<\/b><span style=\"font-weight: 400;\"> in blood banks\u2014whole blood into red cells, plasma, and platelets (see our blood bank centrifuge range)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Urine sediment concentration<\/b><span style=\"font-weight: 400;\"> for microscopic urinalysis<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Gel card processing<\/b><span style=\"font-weight: 400;\"> for blood grouping and cross-matching, run on a fixed, manufacturer-specified cycle<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Serum and plasma separation<\/b><span style=\"font-weight: 400;\"> for biochemistry and pathology<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Pharma sample prep<\/b><span style=\"font-weight: 400;\"> \u2014 QC, stability testing, formulation research<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Cell culture and research<\/b><span style=\"font-weight: 400;\"> \u2014 pelleting cells, DNA\/RNA extraction support<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Labs typically choose between general-purpose bench centrifuges, refrigerated centrifuges for temperature-sensitive samples, and dedicated blood bank centrifuges for transfusion medicine.<\/span><\/p>\n<h2><b>Blood Centrifuge vs. Blood Bank Centrifuge<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A blood bank centrifuge is built for blood bags rather than open tubes, holding single or double bags securely while applying a controlled, protocol-specific RCF so the sample separates into red cells, platelet-rich plasma, and platelet-poor plasma without damaging the bag or cells. Global guidance on blood component processing comes from the <\/span><a href=\"https:\/\/www.who.int\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">WHO<\/span><\/a><span style=\"font-weight: 400;\">, and in the US, from AABB.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Temperature is <\/span><b>not a single universal figure; it depends on the component being processed<\/b><span style=\"font-weight: 400;\">:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Red cell\/whole blood separation:<\/b><span style=\"font-weight: 400;\"> commonly 2\u00b0C\u20138\u00b0C, to preserve red cell viability.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Platelet-rich plasma separation:<\/b><span style=\"font-weight: 400;\"> closer to room temperature, 20\u00b0C\u201324\u00b0C, since platelets can activate or clump if chilled.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Some plasma protocols use programmable sub-zero settings.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Always follow your lab&#8217;s SOP and the manufacturer&#8217;s validated settings rather than one fixed number\u2014this is why refrigerated blood bank centrifuges are built with a wide, programmable temperature range rather than a locked single setting.<\/span><\/p>\n<h2><b>Clinical and Medical Centrifuge Applications<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Clinical\/medical centrifuges serve hospital pathology departments, diagnostic centers, and blood banks for routine processing. They&#8217;re rated for continuous daily use, support swing-out and fixed-angle rotors, and include imbalance detection, lid-lock interlocks, and digital speed\/time\/temperature\/RCF displays\u2014often handling urine, serum, and gel cards on one unit in a single day.<\/span><\/p>\n<h2><b>Centrifuge in Pharma Industry Manufacturing<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Pharma manufacturers use centrifuges for formulation development, active-ingredient purification, and QC sample prep, relying on validated, reproducible <\/span><b>RCF<\/b><span style=\"font-weight: 400;\"> values rather than RPM alone\u2014since inconsistent force between runs, even at matching RPM on different equipment, can affect batch testing and regulatory documentation. See our<\/span><a href=\"https:\/\/bionicsscientific.com\/\"> <span style=\"font-weight: 400;\">pharma lab equipment range<\/span><\/a><span style=\"font-weight: 400;\"> for QC-focused configurations.<\/span><\/p>\n<h2><b>Typical Operating Parameters by Application<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Reference ranges are provided for your reference only; please confirm against your protocol and the rotor&#8217;s actual RCF.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Application<\/b><\/td>\n<td><b>Temperature Range<\/b><\/td>\n<td><b>Force \/ Setting<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Red cell separation (blood bank)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2\u00b0C\u20138\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Protocol-specific RCF (rotor-dependent)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Platelet-rich plasma separation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">20\u00b0C\u201324\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Lower RCF, shorter spin<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Urine sediment<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Ambient<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Low-speed, per lab SOP<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Gel card<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Ambient<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Fixed, manufacturer-specified cycle<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Pharma sample prep\/QC<\/span><\/td>\n<td><span style=\"font-weight: 400;\">4\u00b0C\u201325\u00b0C (model-dependent)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Per validated protocol<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">General serum-plasma separation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Ambient or refrigerated<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Protocol-specific RCF<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Sample Specification \u2014 Refrigerated Blood Bank Centrifuge<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Specification<\/b><\/td>\n<td><b>Details<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Max Speed<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Up to 5,000 RPM (confirm max RCF for the fitted rotor)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Max RCF<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Up to 4,500 x g<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Temperature Range<\/span><\/td>\n<td><span style=\"font-weight: 400;\">-10\u00b0C to +40\u00b0C (programmable)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Capacity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Single\/double blood bag rotor, tube rotor options<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Display<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Digital, with speed, time, temperature, and RCF<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Safety<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Imbalance detection, lid interlock, over-speed protection<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Rotor Type<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Swing-out, fixed-angle (interchangeable\u2014RCF changes with radius)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Power Supply<\/span><\/td>\n<td><span style=\"font-weight: 400;\">220V\/50Hz (export models configurable)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Certification<\/span><\/td>\n<td><span style=\"font-weight: 400;\">ISO-compliant manufacturing<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>How to Select the Right Centrifuge<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Sample format:<\/b><span style=\"font-weight: 400;\"> open tubes, sealed tubes, single or double blood bags each need a different rotor.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Required RCF<\/b><span style=\"font-weight: 400;\">, Not RPM: Check achievable RCF at your protocol&#8217;s settings on the rotor you&#8217;ll actually use.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Temperature control:<\/b><span style=\"font-weight: 400;\"> refrigeration, sub-zero programmability, or ambient-only operation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Rotor interchangeability:<\/b><span style=\"font-weight: 400;\"> swing-out vs. fixed-angle, and whether one unit supports multiple sample types.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Duty cycle:<\/b><span style=\"font-weight: 400;\"> continuous hospital\/blood-bank use has different motor and cooling demands than bench use.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Safety and compliance:<\/b><span style=\"font-weight: 400;\"> imbalance detection, interlocks, over-speed protection, audit-ready documentation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>After-sales support:<\/b><span style=\"font-weight: 400;\"> calibration service, spare rotors\/bag holders, on-site RCF\/temperature validation.<\/span><\/li>\n<\/ul>\n<h2><b>Why Laboratories Choose Bionics Scientific<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Bionics Scientific has manufactured lab equipment for over 35 years, with an installed base across India and markets including Saudi Arabia, the UAE, Oman, Qatar, Kuwait, and the USA. (Milestones \u2014 years in operation, units dispatched \u2014 are backed by registration records, shipment history, and client references available on request for due diligence.)<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Buyers evaluating manufacturers weigh rotor accuracy and documented RCF performance, temperature stability on refrigerated models, after-sales service and spare-part availability, and whether a unit can be customized for a specific blood bank or pharma QC workflow\u2014areas where a dedicated manufacturer, rather than a trading or import-only supplier, tends to make the difference. Explore our centrifuge product range or<\/span><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"> <span style=\"font-weight: 400;\">contact our team<\/span><\/a><span style=\"font-weight: 400;\"> for calibration certificates, RCF\/rotor charts, or export documentation.<\/span><\/p>\n<h2><b>FAQs<\/b><\/h2>\n<p><b>What is the purpose of a lab centrifuge?\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">It separates the components of a fluid sample through sedimentation rate.<\/span><\/p>\n<p><b>Difference between a blood centrifuge and a normal lab centrifuge?\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">A blood bank centrifuge comes with bag holders and refrigeration capacity for blood bags, whereas a normal lab centrifuge is designed for tubes and lacks these features.<\/span><\/p>\n<p><b>Temperature requirement of a blood bank centrifuge?\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The temperature requirement depends upon the component type: 2\u00b0C\u20138\u00b0C for red cells or whole blood and 20\u00b0C\u201324\u00b0C for platelet-rich plasma.<\/span><\/p>\n<p><b>Why does RCF matter more than RPM?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Because RCF determines the actual force exerted on the sample, considering speed and the radius of the rotor. Two different centrifuges operating at the same RPM will have a different force on the sample because of varying rotor sizes; therefore, RCF needs to be checked in the specifications of the machine (not RPM).<\/span><\/p>\n<p><b>Why are gel cards used for centrifugation?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">They are centrifuged in a cycle as provided by the manufacturer, enabling the interaction of the blood with the gel column reagents for grouping and cross-matching.<\/span><\/p>\n<p><b>How is separation of blood components through centrifugation done?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Separation of blood components takes place depending on their sedimentation rate through the force of centrifugation. The red cells, which have the highest density, settle first, followed by the settling of plasma and platelets in layers depending on their density and particle sizes.<\/span><\/p>\n<p><b>Purpose of Centrifuge in pharmaceutical industry?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">For preparation of samples, purification of active ingredients, and quality control tests on formulation.<\/span><\/p>\n<p><b>Why is the urine sample centrifuged?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">To precipitate its sediment in the bottom of the tube.<\/span><\/p>\n<p><b>Is &#8220;center fuse machine&#8221; the same as a centrifuge?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Yes\u2014it&#8217;s a common phonetic misspelling of &#8220;centrifuge machine.&#8221;<\/span><\/p>\n<p><b>How do I select the right centrifuge?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Match equipment to your protocol: sample format, required RCF (not just RPM), temperature control, rotor interchangeability, duty cycle, and manufacturer after-sales\/calibration support.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><i><span style=\"font-weight: 400;\">Setting up a blood bank, upgrading a diagnostic lab, or sourcing pharma QC equipment? Explore our<\/span><\/i><a href=\"https:\/\/www.bionicsscientific.com\/blogs\/centrifuge-machine\/\"> <i><span style=\"font-weight: 400;\">centrifuge product range<\/span><\/i><\/a><i><span style=\"font-weight: 400;\"> or<\/span><\/i><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"> <i><span style=\"font-weight: 400;\">contact our team<\/span><\/i><\/a><i><span style=\"font-weight: 400;\"> for specifications, RCF\/rotor documentation, or export paperwork for the Middle East, USA, and other markets.<\/span><\/i><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Quick answer: A lab centrifuge spins samples at high speed so components separate by density and sedimentation rate\u2014denser material moves [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2763,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[150],"tags":[],"class_list":["post-2762","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-centrifuge"],"uagb_featured_image_src":{"full":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge.png",1774,887,false],"thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge-150x150.png",150,150,true],"medium":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge-300x150.png",300,150,true],"medium_large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge-768x384.png",768,384,true],"large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge-1024x512.png",1024,512,true],"1536x1536":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge-1536x768.png",1536,768,true],"2048x2048":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge.png",1774,887,false],"web-stories-poster-portrait":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge-640x853.png",640,853,true],"web-stories-publisher-logo":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge-96x96.png",96,96,true],"web-stories-thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/lab-centrifuge-150x75.png",150,75,true]},"uagb_author_info":{"display_name":"Team Bionics Scientific Technologies","author_link":"https:\/\/www.bionicsscientific.com\/blogs\/author\/bionicsadmin\/"},"uagb_comment_info":0,"uagb_excerpt":"Quick answer: A lab centrifuge spins samples at high speed so components separate by density and sedimentation rate\u2014denser material moves [&hellip;]","_links":{"self":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2762","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/comments?post=2762"}],"version-history":[{"count":1,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2762\/revisions"}],"predecessor-version":[{"id":2764,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2762\/revisions\/2764"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media\/2763"}],"wp:attachment":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media?parent=2762"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/categories?post=2762"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/tags?post=2762"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}