{"id":2765,"date":"2026-08-27T12:05:07","date_gmt":"2026-08-27T12:05:07","guid":{"rendered":"https:\/\/www.bionicsscientific.com\/blogs\/?p=2765"},"modified":"2026-08-27T12:05:48","modified_gmt":"2026-08-27T12:05:48","slug":"biosafety-cabinet-class-2","status":"publish","type":"post","link":"https:\/\/www.bionicsscientific.com\/blogs\/biosafety-cabinet-class-2\/","title":{"rendered":"Biosafety Cabinet Class II: Working Principle, Types, Specifications, and Buying Guide"},"content":{"rendered":"<h2><b>Quick Answer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A Biosafety Cabinet Class 2 (Class II) is a ventilated, HEPA-filtered enclosure that protects the lab worker, sample, and environment simultaneously through inward, downward, and HEPA-exhaust airflow. It&#8217;s standard containment equipment for risk groups 2 and 3 biological agents in microbiology, virology, cell culture, pharma QC, and diagnostics labs. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">It differs from a plain <\/span><a href=\"https:\/\/www.bionicsscientific.com\/cleanroom-equipment\/laminar-air-flow-cabinet.php\"><span style=\"font-weight: 400;\">Laminar Air Flow<\/span><\/a><span style=\"font-weight: 400;\"> (LAF) unit because LAF protects only the sample, and from Class I because it also protects the product with HEPA-filtered downflow. Bionics Scientific manufactures Class II Type A2 cabinets in India, with 35 years of experience and 1000+ units dispatched across India and overseas, including the Middle East, Saudi Arabia, Oman, and the USA.<\/span><\/p>\n<h2><b>What Is a Biosafety Cabinet?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A biosafety cabinet (BSC) is an enclosed, ventilated workspace built to contain aerosols from infectious or hazardous biological material. Unlike a fume hood, built for chemical vapors, a BSC is purpose-built for biological containment, and unlike an open laminar airflow bench, it protects the operator, not just the material inside.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Every Class II cabinet draws room air through the front grille, splits it, and passes a portion through a HEPA filter before recirculating it as a vertical downflow across the work surface. Remaining air is drawn down through the front grille, preventing aerosols from escaping toward the operator. Exhaust air also passes through a second HEPA filter before leaving, either into the room (Type A2) or through ductwork (Type B1\/B2). This three-way protection \u2014 personnel, product, environment \u2014 separates a true biosafety cabinet from a laminar flow bench.<\/span><\/p>\n<h2><b>Biosafety Cabinet Types and Classes<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Biosafety cabinets fall into three classes based on airflow design and containment level. Class I cabinets protect the operator and environment but not the sample, since air exhausts through a HEPA filter without HEPA-filtered downflow; these are largely superseded by Class II units.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Class II cabinets are the most widely installed type because they protect worker, sample, and room simultaneously. Subtypes vary by recirculation and ducting: Type A1 recirculates roughly 70% of air and may exhaust into the room but isn&#8217;t suited to volatile toxic chemicals. Type A2 is similar but with higher inflow velocity and a negative-pressure plenum\u2014the most common subtype for microbiology and cell culture and what Bionics Scientific manufactures. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Type B1 is partially ducted; Type B2 is fully ducted with no recirculation, used where volatile chemical or radioactive hazards combine with biological risk.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Class III cabinets are gas-tight, glovebox-style enclosures for Risk Group 4 agents, reserved for BSL-4 facilities.<\/span><\/p>\n<h2><b>Biosafety Cabinet vs. Laminar Air Flow (LAF)<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">This distinction matters for safety. An LAF cabinet pushes filtered air across the work surface and exhausts it back into the room with no operator-protection barrier\u2014protecting only the sample. A biosafety cabinet always includes an inward airflow barrier and HEPA filters for exhaust before release, protecting the operator too. As a rule: use a BSC, not an LAF bench, for infectious materials.<\/span><\/p>\n<h2><b>How a Class II Biosafety Cabinet Works<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The blower draws room air through the front intake grille at a manufacturer-specified inflow velocity, per the data plate. This air passes beneath the work surface and up through a supply HEPA filter, forming the vertical downflow across the work area. A front air-split point directs part of this downflow, plus front-grille intake air, into the plenum and through the exhaust HEPA filter. Since both supply and exhaust air pass through HEPA filtration (typically 99.99% efficient at 0.3 microns), particulates and most microorganisms are captured before air recirculates or leaves.<\/span><\/p>\n<h2><b>Specification Table \u2014 Bionics Scientific Class II Type A2 Biosafety Cabinet<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Parameter<\/b><\/td>\n<td><b>Specification<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Class\/Type<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Class II, Type A2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Construction<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Powder-coated \/ SS 304 exterior and interior chamber<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Filtration<\/span><\/td>\n<td><span style=\"font-weight: 400;\">HEPA supply + exhaust filter, efficiency rating on certificate<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Airflow pattern<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Inward, downward, HEPA-recirculated<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Work surface<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Perforated SS 304 removable tray<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Viewing panel<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Sloped, impact-resistant safety glass sash<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">UV germicidal lamp<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Optional, factory-fitted<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Illumination<\/span><\/td>\n<td><span style=\"font-weight: 400;\">LED, shadow-free<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Alarm system<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Airflow\/sash-position audible-visual alarm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Available widths<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2 ft \/ 4 ft \/ 6 ft (custom on request)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Standards<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Aligned with international BSC test standards; site validation per client SOP<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Power supply<\/span><\/td>\n<td><span style=\"font-weight: 400;\">220\u2013240V, 50 Hz (export units configurable to destination voltage)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Cabinet Temperature Behavior \u2014 Indicative Chart<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Interior temperature in a Class II cabinet is a function of ambient lab conditions, blower heat load, and UV\/lighting fixtures\u2014it is not a fixed universal number and should always be verified with a calibrated thermometer at installation and during routine validation. Indicative behavior during a standard duty cycle:<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>Time After Startup<\/strong><\/td>\n<td><strong>Typical Work-Zone Temperature Trend<\/strong><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">0 minutes (cold start)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Approx. equal to ambient room temperature<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">15 minutes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Gradual rise as blower motor and lighting reach operating state<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">30 minutes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Stabilizing range; manufacturer-specified steady-state band<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">60+ minutes (steady state)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Stable, cabinet-specific plateau \u2014 confirm against your unit&#8217;s validation report<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Because actual figures vary by cabinet model, room HVAC load, and UV\/lighting configuration, Bionics Scientific provides temperature and airflow validation data specific to each dispatched unit rather than a single quoted figure.<\/span><\/p>\n<h2><b>Where Class II Biosafety Cabinets Are Used<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Class II cabinets are standard in clinical microbiology, TB culture, virology, vaccine research, cell culture, pharmaceutical QC, and hospital pathology labs. Bionics Scientific&#8217;s cabinets are installed pan-India and dispatched overseas to the Middle East, Saudi Arabia, Oman, and the USA.<\/span><\/p>\n<h2><b>How to Select a Class II Type A2 Cabinet?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Consider the fitment width and take into account the sash height along with flow velocity. Demand HEPA certification along with filter certification (0.3 micron) in the form of an airflow validation report for the unit, in addition to the HEPA certification, and not just the specifications. Check out noise level, illumination, sash alarm calibration, and compatibility for electricity and ducting, and ensure that installation is a part of the delivery and not a chargeable extra at a later stage. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Know the PAO\/DOP testing person for commissioning, whether annual certification facilitates NABL\/GLP\/ISO 17025, spare availability, and after-sales and warranty terms.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The most important aspects are HEPA filter certification, airflow validation per unit, after-sales\/spares availability, and annual revalidation capacity \u2014 only these will make a difference between a genuine manufacturer and a trader. Warning signs include lack of filter certificate, lack of validation report, lack of installation in the quotation, and lack of contact name for services. Ask for a detailed and broken-down quotation with a time frame. Bionics Scientific\u2019s Type A2 cabinets conform to this list comprehensively as standard practice.<\/span><\/p>\n<h2><b>Selection of Manufacturer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Generally, buyers look for HEPA filter certification, airflow validation, after-sales filter support, construction quality, and experience. Bionics Scientific has manufactured clean air devices for 35 years, with 1200+ units installed pan-India and overseas.<\/span><\/p>\n<h2><b>Who Trusts Bionics Scientific<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Bionics Scientific Technologies (P) Ltd., a unit of Kartal Projects Pvt. Ltd., is ISO 9001:2015 certified and supplies equipment to <\/span><a href=\"https:\/\/www.bionicsscientific.com\/company-listed-in.php\"><span style=\"font-weight: 400;\">government organizations<\/span><\/a><span style=\"font-weight: 400;\">, including DRDO, UNICEF, WHO, NSIC, MSME, and ISRO\u2014reflecting the quality-control scrutiny its cabinets are built to withstand.<\/span><\/p>\n<h2><b>Validation &amp; Compliance<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Kartal Projects Pvt. Ltd. holds independently issued, currently valid certifications from Euroglobe Registrars (UK):<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Certification<\/b><\/td>\n<td><b>Standard<\/b><\/td>\n<td><b>Certificate No.<\/b><\/td>\n<td><b>Valid Until<\/b><\/td>\n<td><b>Scope<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Quality Management System<\/span><\/td>\n<td><span style=\"font-weight: 400;\">ISO 9001:2015<\/span><\/td>\n<td><span style=\"font-weight: 400;\">184876<\/span><\/td>\n<td><span style=\"font-weight: 400;\">30-03-2029<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Products as per annexure<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">CE Compliance<\/span><\/td>\n<td><span style=\"font-weight: 400;\">MDD 93\/42\/EEC<\/span><\/td>\n<td><span style=\"font-weight: 400;\">184877<\/span><\/td>\n<td><span style=\"font-weight: 400;\">30-03-2029<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Products as per annexure<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Good Manufacturing Practices<\/span><\/td>\n<td><span style=\"font-weight: 400;\">GMP<\/span><\/td>\n<td><span style=\"font-weight: 400;\">184878<\/span><\/td>\n<td><span style=\"font-weight: 400;\">30-03-2029<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Explicitly includes fume hood and biosafety cabinet<\/span><\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.nsf.org\/lab-testing\/biosafety-cabinetry\/biosafety-cabinet-certification\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">NSF Certification<\/span><\/a><\/td>\n<td><span style=\"font-weight: 400;\">NSF\/ANSI 61<\/span><\/td>\n<td><span style=\"font-weight: 400;\">183884<\/span><\/td>\n<td><span style=\"font-weight: 400;\">08-03-2027<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Scoped to biosafety cabinet manufacture<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">All four remain in active surveillance and are verifiable through the certifying body.<\/span><\/p>\n<p><i>The Bionics Scientific Product Engineering Team has reviewed this information for technical accuracy.<\/i><\/p>\n<h2><b>Frequently Asked Questions<\/b><\/h2>\n<p><b>What is a biosafety cabinet class 2?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A HEPA-filtered, ventilated enclosure that protects the operator, sample, and environment through inward and HEPA-recirculated downward airflow\u2014the standard for risk group 2\/3 biological material.<\/span><\/p>\n<p><b>What is the difference between LAF and a biosafety cabinet?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">LAF filters air onto the work surface with no inward barrier, protecting only the sample. A biosafety cabinet adds an inward barrier and HEPA-filters exhaust, protecting the operator too.<\/span><\/p>\n<p><b>What is the difference between Type A2 and Type B2?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Type A2 recirculates part of its filtered air and typically exhausts into the room. Type B2 is a total-exhaust, fully ducted design for volatile chemical or radioactive hazards.<\/span><\/p>\n<p><b>Is a biosafety cabinet the same as a fume hood?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">No. A fume hood extracts chemical vapor, not biological aerosols, and doesn&#8217;t HEPA-filter its exhaust like a biosafety cabinet does.<\/span><\/p>\n<p><b>What maintenance does a Class II cabinet need?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Periodic HEPA filter integrity testing (DOP\/PAO challenge), airflow velocity verification, UV lamp checks, and sash-alarm calibration \u2014 typically annually or per your quality system&#8217;s schedule.<\/span><\/p>\n<p><b>Are Bionics Scientific&#8217;s biosafety cabinets certified and exportable?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Yes. Kartal Projects Pvt Ltd holds valid ISO 9001:2015, CE, GMP, and NSF\/ANSI 61 certificates covering biosafety cabinet manufacture, and cabinets can be configured for export to the Middle East, Saudi Arabia, Oman, and the USA.<\/span><\/p>\n<h2><b>Get a Validated Biosafety Cabinet for Your Lab<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Choosing the right Class II biosafety cabinet means choosing a manufacturer who backs every specification with validation data. Bionics Scientific has spent 35 years manufacturing clean-air equipment and dispatched 1200+ units across India and overseas. <\/span><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"><span style=\"font-weight: 400;\">Talk to our team <\/span><\/a><span style=\"font-weight: 400;\">for a site-specific specification sheet, HEPA validation report, and installation support for your Class II biosafety cabinet requirement.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Quick Answer A Biosafety Cabinet Class 2 (Class II) is a ventilated, HEPA-filtered enclosure that protects the lab worker, sample, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2766,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[98],"tags":[],"class_list":["post-2765","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cleanroom-equipment"],"uagb_featured_image_src":{"full":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2.png",1774,887,false],"thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2-150x150.png",150,150,true],"medium":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2-300x150.png",300,150,true],"medium_large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2-768x384.png",768,384,true],"large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2-1024x512.png",1024,512,true],"1536x1536":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2-1536x768.png",1536,768,true],"2048x2048":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2.png",1774,887,false],"web-stories-poster-portrait":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2-640x853.png",640,853,true],"web-stories-publisher-logo":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2-96x96.png",96,96,true],"web-stories-thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/08\/biosafety-cabinet-class-2-150x75.png",150,75,true]},"uagb_author_info":{"display_name":"Team Bionics Scientific Technologies","author_link":"https:\/\/www.bionicsscientific.com\/blogs\/author\/bionicsadmin\/"},"uagb_comment_info":0,"uagb_excerpt":"Quick Answer A Biosafety Cabinet Class 2 (Class II) is a ventilated, HEPA-filtered enclosure that protects the lab worker, sample, [&hellip;]","_links":{"self":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2765","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/comments?post=2765"}],"version-history":[{"count":2,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2765\/revisions"}],"predecessor-version":[{"id":2768,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2765\/revisions\/2768"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media\/2766"}],"wp:attachment":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media?parent=2765"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/categories?post=2765"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/tags?post=2765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}