{"id":2799,"date":"2026-09-04T09:35:44","date_gmt":"2026-09-04T09:35:44","guid":{"rendered":"https:\/\/www.bionicsscientific.com\/blogs\/?p=2799"},"modified":"2026-09-04T09:37:51","modified_gmt":"2026-09-04T09:37:51","slug":"cryo-freeze","status":"publish","type":"post","link":"https:\/\/www.bionicsscientific.com\/blogs\/cryo-freeze\/","title":{"rendered":"Cryo Freeze Systems: Deep Freezers &#038; Cold Storage Guide"},"content":{"rendered":"<h2><b>Quick Answer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Cryo freeze&#8221; is used two ways in this space. Strictly, it refers to cryogenic-range freezing\u2014storage at or near -80\u00b0C and below, using ULT freezers or liquid nitrogen\/vapor-phase systems\u2014for samples like cell lines, plasma, and biological repositories. More broadly, buyers use &#8220;cryo freeze&#8221; as a search term for any deep-cold or sub-zero storage need, including <\/span><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-refrigerator\/laboratory-deep-freezer.php\"><span style=\"font-weight: 400;\">deep freezers<\/span><\/a><span style=\"font-weight: 400;\">, walk-in cold rooms, laboratory refrigerators, pharmacy fridges, and mortuary chambers. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">This guide covers that broader equipment category, since that&#8217;s what most buyers searching the term are actually comparing\u2014but the distinction matters if your requirement is specifically cryogenic\/ULT storage rather than general deep-cold storage.<\/span><\/p>\n<h2><b>What Buyers Are Actually Trying to Solve<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Most buyers researching &#8220;cryo freeze&#8221; aren&#8217;t shopping for one machine\u2014they&#8217;re trying to match a storage problem to the right equipment class. A hospital blood bank, a vaccine distributor, a research lab, and a mortuary each need controlled cold storage, but at different temperatures, volumes, and compliance levels. The questions buyers actually ask are rarely about the marketing term; they&#8217;re about set-point accuracy, recovery time after a power cut, and whether the manufacturer can prove its certifications. That&#8217;s the lens this guide uses.<\/span><\/p>\n<h2><b>Certification Buyers Should Check First<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Before comparing specs, buyers typically want to know who&#8217;s behind the equipment. Bionics Scientific is a manufacturing unit of Kartal Projects Pvt Ltd, Delhi, with 35 years in the sector. Kartal Projects holds certification listed as ISO 9001:2015 (Cert. No. 184876), CE under MDD 93\/42\/EEC (Cert. No. 184877), GMP (Cert. No. 184878), and NSF\/ANSI 61 (Cert. No. 183884), issued by Euroglobe Registrars, a UK certification body established in 2007 (13-14 Old Square, London WC2A 3UT). <\/span><\/p>\n<p><i><span style=\"font-weight: 400;\">Certificate numbers, dates, and scope should be confirmed against the current, valid certificate copies before this is published, since compliance certificates are subject to renewal and scope changes.<\/span><\/i><span style=\"font-weight: 400;\"> The GMP annexure lists laboratory refrigerators, deep freezers, and mortuary chambers within its scope.<\/span><\/p>\n<h2><b>Deep Freezers and Ultra-Low-Temperature (ULT) Storage<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Cold-storage equipment is easiest to compare when the temperature bands don&#8217;t overlap. A clean breakdown:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Standard deep freezer<\/b><span style=\"font-weight: 400;\">: -20\u00b0C to -40\u00b0C\u2014general reagent and sample storage<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ultra-low-temperature (ULT) freezer<\/b><span style=\"font-weight: 400;\">: -40\u00b0C to -86\u00b0C\u2014vaccine banks, plasma, and biological repositories requiring cryogenic-range preservation<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Deep freezer sizes range from 100-litre bench units to 500-litre-plus upright cabinets, scaling to multi-door or walk-in configurations for bulk inventory. Buyers evaluating either category should check:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Temperature uniformity<\/b><span style=\"font-weight: 400;\"> across shelves, not just at the sensor<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Recovery time<\/b><span style=\"font-weight: 400;\"> after door openings<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Backup power and alarm systems\u2014a<\/b><span style=\"font-weight: 400;\"> ULT excursion can destroy an entire vaccine batch<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Insulation thickness<\/b><span style=\"font-weight: 400;\">, which affects both stability and running cost<\/span><\/li>\n<\/ul>\n<h2><b>Walk-In Cold Rooms and Walk-In Chillers<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">When volume exceeds what a cabinet freezer can hold, walk-in cold rooms and chillers are built as modular panel systems. There&#8217;s no single universal temperature that defines a &#8220;walk-in &#8220;chiller&#8221;\u2014the set-point is commissioned around the product being stored: 2\u00b0C\u20138\u00b0C for pharmaceuticals, 15\u00b0C\u201325\u00b0C for climate-controlled ambient goods, or sub-zero for frozen inventory and biologics. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">What buyers should confirm before ordering: the exact set-point required for their product, plus panel thickness, refrigeration load calculation, and door-seal design\u2014these determine whether the room holds that set-point under real door traffic, not just on a spec sheet.<\/span><\/p>\n<h2><b>Laboratory Refrigerators<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Laboratory refrigerators use forced-air circulation instead of static cooling, with continuous temperature logging and, where required, explosion-safe interiors. A laboratory refrigerator diagram typically shows a sealed cabinet, a top- or rear-mounted compressor, a forced-air evaporator coil circulating through perforated shelving, and a digital controller with a high\/low alarm relay. That&#8217;s what separates a lab-grade unit from a repurposed household fridge: even cycling and no cold spots, not just a low average reading. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Bionics Scientific&#8217;s <\/span><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-refrigerator\/\"><span style=\"font-weight: 400;\">laboratory refrigerators<\/span><\/a><span style=\"font-weight: 400;\"> are manufactured under the same NSF\/ANSI 61-certified quality system (Cert. No. 183884) that covers the company&#8217;s laboratory and scientific equipment scope\u2014note that NSF\/ANSI 61 itself is a standard for materials and components in contact with drinking water, so buyers with water-contact requirements (e.g., water distillers, RO systems) should confirm the certificate&#8217;s exact applicability to their specific product before relying on it as a product-level claim.<\/span><\/p>\n<h2><b>Pharmacy Fridges<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Pharmacy fridges hold the 2\u00b0C\u20138\u00b0C band required for vaccines, insulin, and <\/span><a href=\"https:\/\/www.who.int\/teams\/health-product-policy-and-standards\/standards-and-specifications\/vaccine-standardization\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">temperature-sensitive medication<\/span><\/a><span style=\"font-weight: 400;\">. Buyers in this category usually prioritize data logging as standard, door type based on stock visibility, and audible\/visual alarms for any deviation\u2014increasingly a requirement in pharmacy cold-chain audits, not an optional extra.<\/span><\/p>\n<h2><b>Mortuary Chambers and Preservation Units<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Mortuary storage needs depend on duration. Short-term holding runs 2\u00b0C to 4\u00b0C; extended preservation chambers\u2014sometimes called a &#8220;dead fridge&#8221; informally\u2014sustain -15\u00b0C to -20\u00b0C. Chambers are supplied single-body, multi-body, or walk-in, with corrosion-resistant interiors and independent refrigeration circuits per chamber, so one compressor failure doesn&#8217;t take down the whole unit. <\/span><a href=\"https:\/\/www.bionicsscientific.com\/blogs\/mortuary-chamber-dead-body-box\/\"><span style=\"font-weight: 400;\">Mortuary chambers<\/span><\/a><span style=\"font-weight: 400;\"> are named in the GMP certificate annexure (Cert. No. 184878).<\/span><\/p>\n<h2><b>Specification Reference Table<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Equipment Type<\/b><\/td>\n<td><b>Typical Temperature Range<\/b><\/td>\n<td><b>Common Configuration<\/b><\/td>\n<td><b>Primary Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Pharmacy Fridge<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2\u00b0C to 8\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Single\/double door<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Vaccines, insulin, medicines<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Laboratory Refrigerator<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2\u00b0C to 8\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Forced-air, upright<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Reagents, samples, media<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Standard Deep Freezer<\/span><\/td>\n<td><span style=\"font-weight: 400;\">-20\u00b0C to -40\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Upright\/chest, multi-door<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Reagent and sample storage<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">ULT Freezer<\/span><\/td>\n<td><span style=\"font-weight: 400;\">-40\u00b0C to -86\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Upright, multi-door<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Vaccine banks, plasma, repositories<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Walk-In Chiller<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Setpoint per application (typically 2\u00b0C\u201325\u00b0C)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Modular panel room<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Bulk pharma, ambient goods<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Walk-In Cold Room<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Set point per application (chilled to sub-zero)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Pre-fabricated panels<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Bulk cold storage, distribution<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Mortuary Chamber (short-term)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2\u00b0C to 4\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Single\/multi-body<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Hospital mortuary<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Mortuary Chamber (preservation)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">-15\u00b0C to -20\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Single\/multi-body<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Extended preservation<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Temperature Chart at a Glance<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><strong>Temperature Band<\/strong><\/td>\n<td><strong>Equipment \/ Application<\/strong><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">2\u00b0C to 8\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Pharmacy Fridge\/Laboratory Refrigerator<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">2\u00b0C to 4\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Mortuary Short-Term Storage<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">-15\u00b0C to -20\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Mortuary Preservation<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">-20\u00b0C to -40\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Standard Deep Freezer<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">-40\u00b0C to -86\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">ULT Freezer (cryogenic-range storage)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Setpoint per application<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Walk-In Chiller \/ Walk-In Cold Room<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>What Buyers Should Verify Before Ordering<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Manufacturer certification\u2014ask<\/b><span style=\"font-weight: 400;\"> for certificate numbers and confirm current validity directly with the issuing body, not just from marketing material<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Load-tested capacity<\/b><span style=\"font-weight: 400;\">, not nameplate capacity<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Compressor redundancy<\/b><span style=\"font-weight: 400;\"> for critical inventory (vaccine banks, plasma, mortuary preservation)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>After-sales service network\u2014cold-chain<\/b><span style=\"font-weight: 400;\"> failure is time-sensitive, not a routine repair<\/span><\/li>\n<\/ul>\n<h2><b>Cryo Freeze Equipment: Serving Global Cold-Chain Markets<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Bionics Scientific supplies and supports deployments across the United States (USA), United Kingdom (UK), United Arab Emirates (UAE), Saudi Arabia, South Africa, Canada, Australia, Singapore, Malaysia, the Philippines, Indonesia, Kenya, Nigeria, Bangladesh, Nepal, Qatar, Oman, Kuwait, Bahrain, Vietnam, Thailand, Tanzania, Ghana, Sri Lanka, and New Zealand, alongside pan-India distribution.<\/span><\/p>\n<h2><b>Frequently Asked Questions<\/b><\/h2>\n<p><b>What does &#8220;cryo freeze&#8221; actually mean?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Strictly, cryogenic-range freezing at or below roughly -80\u00b0C. In everyday buyer searches, it&#8217;s also used broadly to mean any deep-cold storage equipment\u2014deep freezers, cold rooms, lab refrigerators, and mortuary chambers.<\/span><\/p>\n<p><b>What temperature should a pharmacy fridge maintain?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">2\u00b0C to 8\u00b0C continuously, with alarms on any deviation.<\/span><\/p>\n<p><b>What&#8217;s the difference between a walk-in chiller and a walk-in cold room?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Both are modular panel rooms; &#8220;chiller&#8221; usually refers to above-freezing set-points, while &#8220;cold room&#8221; can be configured chilled or sub-zero\u2014the exact set-point is application-specific, not a fixed number.<\/span><\/p>\n<p><b>What deep freezer sizes are available for lab use?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">From bench-top 100-litre models to upright 500-litre-plus cabinets, up to multi-door and walk-in configurations for bulk storage.<\/span><\/p>\n<p><b>What&#8217;s the difference between a standard deep freezer and a ULT freezer?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Standard deep freezers run -20\u00b0C to -40\u00b0C for general reagent and sample storage; ULT freezers run -40\u00b0C to -86\u00b0C for vaccine banks, plasma, and biological repositories needing cryogenic-range preservation.<\/span><\/p>\n<p><b>What temperature is used for mortuary storage?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">2\u00b0C to 4\u00b0C short-term; -15\u00b0C to -20\u00b0C for extended preservation units.<\/span><\/p>\n<p><b>Is a &#8220;dead fridge&#8221; the same as a mortuary chamber?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">It&#8217;s an informal term some buyers use\u2014the correct technical term is &#8220;mortuary chamber&#8221; or &#8220;body preservation unit.&#8221;<\/span><\/p>\n<p><b>What certifications should a cold storage manufacturer hold?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">ISO 9001:2015 for quality management, CE for regulatory conformity, GMP for manufacturing practice, and, for water-contact components specifically, NSF\/ANSI 61.<\/span><\/p>\n<p><b>Does NSF\/ANSI 61 certify laboratory refrigerators?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Not directly\u2014NSF\/ANSI 61 is a standard for materials and components in contact with drinking water. Buyers should confirm exactly what a manufacturer&#8217;s NSF\/ANSI 61 certificate covers rather than assuming it applies to all lab equipment.<\/span><\/p>\n<p><b>Does Bionics Scientific export cryo-freeze equipment internationally?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Yes, to markets across the Middle East, Africa, Southeast Asia, and beyond, alongside pan-India supply.<\/span><\/p>\n<h2><b>Get the Right Cryo-Freeze Solution for Your Facility<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The right choice comes down to your required temperature band, volume, and compliance obligations\u2014not the search term used to find it. Contact <\/span><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"><span style=\"font-weight: 400;\">Bionics Scientific&#8217;s engineering team<\/span><\/a><span style=\"font-weight: 400;\"> to specify equipment matched to your exact storage requirements, backed by ISO 9001:2015, CE, and GMP certified manufacturing.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Quick Answer Cryo freeze&#8221; is used two ways in this space. Strictly, it refers to cryogenic-range freezing\u2014storage at or near [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2800,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[148],"tags":[],"class_list":["post-2799","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-freeze-dryers-lyophilizers"],"uagb_featured_image_src":{"full":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze.png",1774,887,false],"thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze-150x150.png",150,150,true],"medium":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze-300x150.png",300,150,true],"medium_large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze-768x384.png",768,384,true],"large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze-1024x512.png",1024,512,true],"1536x1536":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze-1536x768.png",1536,768,true],"2048x2048":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze.png",1774,887,false],"web-stories-poster-portrait":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze-640x853.png",640,853,true],"web-stories-publisher-logo":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze-96x96.png",96,96,true],"web-stories-thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/09\/cryo-freeze-150x75.png",150,75,true]},"uagb_author_info":{"display_name":"Team Bionics Scientific Technologies","author_link":"https:\/\/www.bionicsscientific.com\/blogs\/author\/bionicsadmin\/"},"uagb_comment_info":0,"uagb_excerpt":"Quick Answer Cryo freeze&#8221; is used two ways in this space. Strictly, it refers to cryogenic-range freezing\u2014storage at or near [&hellip;]","_links":{"self":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2799","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/comments?post=2799"}],"version-history":[{"count":3,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2799\/revisions"}],"predecessor-version":[{"id":2803,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/2799\/revisions\/2803"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media\/2800"}],"wp:attachment":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media?parent=2799"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/categories?post=2799"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/tags?post=2799"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}