{"id":3037,"date":"2026-10-10T06:20:09","date_gmt":"2026-10-10T06:20:09","guid":{"rendered":"https:\/\/www.bionicsscientific.com\/blogs\/?p=3037"},"modified":"2026-10-10T06:20:09","modified_gmt":"2026-10-10T06:20:09","slug":"double-door-autoclave","status":"publish","type":"post","link":"https:\/\/www.bionicsscientific.com\/blogs\/double-door-autoclave\/","title":{"rendered":"Double Door Autoclave: Specifications, Working Principle, and Buying Guide"},"content":{"rendered":"<h2><b>Quick Answer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A <\/span><a href=\"https:\/\/www.bionicsscientific.com\/autoclave-sterilizer\/double-door-autoclave-sterilizer.php\"><span style=\"font-weight: 400;\">double door autoclave<\/span><\/a><span style=\"font-weight: 400;\"> is a steam sterilizer built with two doors. You load from one side, and the sterilized goods come out from the other. Nothing travels back through the dirty side, which is the key feature. Bionics Scientific has been building autoclaves for 35 years, and our range covers double-door, vertical, fully automatic, and industrial units.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Used in:<\/b><span style=\"font-weight: 400;\"> pharma plants, biotech labs, hospitals, cleanrooms, food labs<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Common cycles:<\/b><span style=\"font-weight: 400;\"> 121 \u00b0C for 15 to 20 minutes, or 134 \u00b0C for 3 to 10 minutes<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Chamber volume:<\/b><span style=\"font-weight: 400;\"> roughly 100 L up to several thousand liters<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Controls:<\/b><span style=\"font-weight: 400;\"> microprocessor or PLC, with a printer or data export<\/span><\/li>\n<\/ul>\n<h2><b>What a Double Door Autoclave Actually Does<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Steam under pressure kills bacteria, spores, fungi, and viruses. Any autoclave does that. What sets this one apart is the wall it sits in. The loading door opens into a general work area, and the unloading door opens into a clean room or a sterile store. The two doors are interlocked, so they can never stand open together.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Auditors like this layout because the process itself blocks mix-ups. A tray cannot be picked up from the wrong side, since the wrong side has no door. That is why pharmaceutical plants, tissue culture units, and hospital sterile supply departments ask for it by name.<\/span><\/p>\n<h2><b>How the Cycle Runs<\/b><\/h2>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Staff load media, glassware, instruments, or waste on the non-sterile side and shut the door.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A vacuum pump or steam flush pulls out trapped air. Air pockets stop steam from reaching the load, so this step matters more than most buyers expect.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Steam fills the jacket and chamber until the set temperature is reached.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The sterilization phase holds that temperature for the programmed time.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Steam is exhausted, and a vacuum dries the load.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The sterile-side door unlocks only once chamber pressure is safe.<\/span><\/li>\n<\/ol>\n<h2><b>Double Door vs. Vertical Autoclave<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">People who type &#8220;<\/span><a href=\"https:\/\/www.bionicsscientific.com\/autoclave-sterilizer\/vertical-type-autoclave-steam-sterilizer.php\"><span style=\"font-weight: 400;\">vertical autoclave machine<\/span><\/a><span style=\"font-weight: 400;\">&#8221; into a search bar are often really deciding between two layouts, so let us be direct about it.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A vertical autoclave loads from the top. It fits small labs, clinics, and field setups where floor space is tight. A fully automatic vertical autoclave adds auto fill, auto cycle, and auto exhaust, which saves operator time, but it still has a single opening. A vertical high-pressure steam sterilizer autoclave stays a sensible pick for media preparation and small instrument loads.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A double door model is horizontal and made for volume plus separation. If you run more than a few baskets a day, or your quality system demands a validated barrier between zones, choose the double door format.<\/span><\/p>\n<h2><b>What Goes Into a Bionics Scientific Double Door Autoclave<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">SS 316L inner chamber, SS 304 outer cladding<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pressure vessel designed with margin above its working pressure<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Electric heating or a steam generator, whichever suits your site<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Door interlocks, safety valve, over-temperature cut-off, and low-water cut-off<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Fractional vacuum pre-conditioning for porous loads<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cycle printer, USB, or software export for audit records<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Trolleys and racks made to your tray size<\/span><\/li>\n<\/ul>\n<h2><b>Double Door Autoclave Specifications<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Our double-door autoclaves are made for dependable steam sterilization in pharmaceutical plants, hospitals, and laboratories. Each unit combines a stainless steel chamber, automatic controls, and layered safety protection.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>Parameter<\/strong><\/td>\n<td><strong>Typical Specification<\/strong><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Horizontal, double door<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Chamber capacity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">100 to 3000 liters<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Chamber material<\/span><\/td>\n<td><span style=\"font-weight: 400;\">SS 316L stainless steel<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Outer body<\/span><\/td>\n<td><span style=\"font-weight: 400;\">SS 304 or mild steel<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Operating temperature<\/span><\/td>\n<td><span style=\"font-weight: 400;\">121 \u00b0C to 134 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Working pressure<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Approx. 15 to 30 psi<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Heating system<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Electric or steam<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Control system<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Microprocessor or PLC<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Door mechanism<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Safety interlocked<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Safety features<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Pressure relief valve, alarms<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Applications<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Pharma, hospitals, laboratories<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Specifications change with model, capacity, and customization.<\/span><\/p>\n<h2><b>Temperature, Pressure, and Time Chart<\/b><\/h2>\n<p><a href=\"https:\/\/www.cdc.gov\/infection-control\/hcp\/disinfection-sterilization\/steam-sterilization.html\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">Sterilization time<\/span><\/a><span style=\"font-weight: 400;\"> depends on the temperature you pick, what is inside the chamber, and the cycle selected.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Temperature<\/b><\/td>\n<td><b>Pressure (approx.)<\/b><\/td>\n<td><b>Holding time<\/b><\/td>\n<td><b>Typical load<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">115\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10 psi<\/span><\/td>\n<td><span style=\"font-weight: 400;\">30 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Selected culture media<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">121\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">15 psi<\/span><\/td>\n<td><span style=\"font-weight: 400;\">15 to 30 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Glassware, instruments<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">126\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">20 psi<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10 to 20 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Compatible textile loads<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">134\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">30 psi<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3 to 18 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Surgical instruments<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Pressures are approximate gauge values. Holding times are illustrative and need validation for your load. Total cycle time also includes heating, air removal, and cooling or drying.<\/span><\/p>\n<h2><b>Where These Machines Earn Their Place<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Pharma and biotech:<\/b><span style=\"font-weight: 400;\"> terminal sterilization, vials and stoppers, material entering a cleanroom<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Hospitals and CSSD:<\/b><span style=\"font-weight: 400;\"> instrument sets, linen, dressing drums<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Research and tissue culture labs:<\/b><span style=\"font-weight: 400;\"> media, plasticware, biohazard waste<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Food and beverage:<\/b><span style=\"font-weight: 400;\"> microbial test labs and container validation<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Industry:<\/b><span style=\"font-weight: 400;\"> as an industrial autoclave for composites, rubber, and large bulk items<\/span><\/li>\n<\/ul>\n<h2><b>15 Things to Check Before You Buy<\/b><\/h2>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Chamber size against your real daily batch<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Load type: liquids, wrapped goods, waste, or porous items<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Vacuum or gravity air removal<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">SS 316L chamber grade<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pressure vessel design code and test certificate<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">How good the interlock between the two doors is<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Steam source: built-in generator or plant steam<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Validation help: IQ, OQ, and PQ<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Data logging and 21 CFR Part 11 readiness if you need it<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Safety devices and emergency stop<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Spare parts availability in your country<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Installation and operator training<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Warranty and annual maintenance terms<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Utilities: power, water, drain, compressed air<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ten-year running cost, not only the purchase price<\/span><\/li>\n<\/ol>\n<h2><b>Autoclave Drum Price: Why There Is No Single Number<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Plenty of buyers search for autoclave drum price, and a fair answer is that one figure does not exist. Chamber volume, steel grade, steam generator, vacuum system, PLC level, door type, and paperwork all move the cost. A compact vertical unit sits far below a validated double door system. Share your load details with us, and we will quote for what you actually need.<\/span><\/p>\n<h2><b>Shipping to Your Country<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Bionics Scientific supplies autoclaves to laboratories and manufacturers in the United States (USA), United Kingdom (UK), United Arab Emirates (UAE), Saudi Arabia, South Africa, Canada, Australia, Singapore, Malaysia, the Philippines, Indonesia, Kenya, Bangladesh, Nepal, Qatar, Oman, Kuwait, Bahrain, Vietnam, Thailand, Tanzania, Ghana, Sri Lanka, and New Zealand. We handle export packing, voltage matching, and shipping documents for each destination.<\/span><\/p>\n<h2><b>Why Buyers Choose Bionics Scientific<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">We have manufactured laboratory and industrial equipment for 35 years. Each autoclave is built in our own facility, pressure tested, and inspected before it ships. Our engineers help with chamber sizing, cycle design, and room layout, and our service team supports commissioning and later care. You deal with the maker directly, so lead times and pricing stay clear.<\/span><\/p>\n<h2><b>Frequently Asked Questions<\/b><\/h2>\n<p><b>For what purpose do I need a double door autoclave?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">It is intended for sterilization of media, instruments, glassware, and wastes in separate chambers. Most popular among pharmaceutical companies, hospitals, and cleanrooms.<\/span><\/p>\n<p><b>How is it different from a vertical autoclave?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The vertical autoclave has a top-loading chamber with a volume not exceeding 80-90 liters. The double-door unit is horizontal, has two interlocked doors and higher chamber capacity.<\/span><\/p>\n<p><b>At what temperature does an autoclave work?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">121 \u00b0C and 134 \u00b0C are standard temperatures used in autoclave cycles. Heat-sensitive materials undergo sterilization at 115\u00b0C cycles.<\/span><\/p>\n<p><b>How long does one cycle last?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">The holding time at 121\u00b0C is 15-20 minutes. Heating and drying times added to it will result in the total cycle time from 45 to 90 minutes.<\/span><\/p>\n<p><b>Can two doors be opened simultaneously?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">No. Electrical and mechanical interlocking allows you to open just one door and prevents contamination of sterile chamber.<\/span><\/p>\n<p><b>What volumes are available?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Capacities start from 100 liters up to several thousand liters, and custom dimensions are also possible.<\/span><\/p>\n<p><b>Do you produce vertical autoclaves too?<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Yes. In addition to double-door autoclaves, our product range includes vertical, fully automatic, and industrial autoclaves.<\/span><\/p>\n<h2><b>Request a Quote Today<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Send us your chamber size, load type and country, and Bionics. Scientific will recommend the right double door or vertical autoclave with a clear quotation.<\/span><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"> <b>Contact our team<\/b><\/a><b> today for specifications, drawings, and pricing.<\/b><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Quick Answer A double door autoclave is a steam sterilizer built with two doors. You load from one side, and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3038,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3037","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-autoclave"],"uagb_featured_image_src":{"full":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave.png",1774,887,false],"thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave-150x150.png",150,150,true],"medium":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave-300x150.png",300,150,true],"medium_large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave-768x384.png",768,384,true],"large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave-1024x512.png",1024,512,true],"1536x1536":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave-1536x768.png",1536,768,true],"2048x2048":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave.png",1774,887,false],"web-stories-poster-portrait":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave-640x853.png",640,853,true],"web-stories-publisher-logo":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave-96x96.png",96,96,true],"web-stories-thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/double-door-autoclave-150x75.png",150,75,true]},"uagb_author_info":{"display_name":"Team Bionics Scientific Technologies","author_link":"https:\/\/www.bionicsscientific.com\/blogs\/author\/bionicsadmin\/"},"uagb_comment_info":0,"uagb_excerpt":"Quick Answer A double door autoclave is a steam sterilizer built with two doors. You load from one side, and [&hellip;]","_links":{"self":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3037","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/comments?post=3037"}],"version-history":[{"count":1,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3037\/revisions"}],"predecessor-version":[{"id":3039,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3037\/revisions\/3039"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media\/3038"}],"wp:attachment":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media?parent=3037"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/categories?post=3037"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/tags?post=3037"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}