{"id":3047,"date":"2026-10-13T08:43:27","date_gmt":"2026-10-13T08:43:27","guid":{"rendered":"https:\/\/www.bionicsscientific.com\/blogs\/?p=3047"},"modified":"2026-10-13T09:09:38","modified_gmt":"2026-10-13T09:09:38","slug":"ice-lined-refrigerator-temperature","status":"publish","type":"post","link":"https:\/\/www.bionicsscientific.com\/blogs\/ice-lined-refrigerator-temperature\/","title":{"rendered":"Ice lined Refrigerator Temperature: Safe Range, Holdover, and Vaccine Storage Guide"},"content":{"rendered":"<p><b>Model evidence:<\/b><span style=\"font-weight: 400;\"> Specifications come from the<\/span><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-refrigerator\/ice-lined-refrigerator.php\"> <span style=\"font-weight: 400;\">Bionics Scientific ILR product page<\/span><\/a><span style=\"font-weight: 400;\">. Test reports and certificates are supplied as agreed in the quotation.<\/span><\/p>\n<h2><b>Quick Answer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An ice lined refrigerator temperature (ILR) keeps vaccines between +2\u00b0C and +8\u00b0C (35.6\u00b0F to 46.4\u00b0F) and uses a lining of frozen water packs to slow warming during power cuts.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Range:<\/b><span style=\"font-weight: 400;\"> +2\u00b0C to +8\u00b0C. Freeze risk can exist near the lining, so placement matters.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Holdover:<\/b><span style=\"font-weight: 400;\"> model-specific; use the tested figure and conditions.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>ILR vs. deep freezer:<\/b><span style=\"font-weight: 400;\"> different equipment with different jobs.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Monitoring:<\/b><span style=\"font-weight: 400;\"> read daily, log minimum and maximum, act on every excursion.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Price:<\/b><span style=\"font-weight: 400;\"> depends on model and options; request a written quotation.<\/span><\/li>\n<\/ul>\n<h2><b>What Is an Ice-Lined Refrigerator?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An ice-lined refrigerator, also called an ILR fridge or ice line refrigerator, is a vaccine refrigerator with water-filled panels around the cabinet. The compressor freezes the water during normal power hours. When power fails, the melting ice absorbs heat and slows the temperature rise.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The lining stabilizes temperature but does not make freezing impossible. The area near it can fall below +2\u00b0C depending on design, loading, and ambient conditions, so check freeze-protection data for your model. Bionics Scientific is a laboratory equipment manufacturer with 35 years of manufacturing experience.<\/span><\/p>\n<h2><b>ILR Temperature Range Explained<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Zone<\/b><\/td>\n<td><b>Celsius<\/b><\/td>\n<td><b>Fahrenheit<\/b><\/td>\n<td><b>Meaning<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Freeze risk<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Below +2\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Below 35.6\u00b0F<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Can permanently damage freeze-sensitive vaccines, often invisibly.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Storage band<\/span><\/td>\n<td><span style=\"font-weight: 400;\">+2\u00b0C to +8\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">35.6\u00b0F to 46.4\u00b0F<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Accepted band for most refrigerated vaccines<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Heat risk<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Above +8\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Above 46.4\u00b0F<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Reduces potency; check vaccine vial monitor (VVM) status.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Use the set point in the manual. Lowering it for extra holdover increases freeze risk.<\/span><\/p>\n<h2><b>Holdover Time<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Holdover is how long the cabinet stays within +2\u00b0C to +8\u00b0C after power stops. It depends on the model, room temperature, loading, and lid openings. Bionics Scientific states that its ILR models have a holdover time of 20 to 24 hours; please confirm the test conditions for each model in the quotation.<\/span><\/p>\n<h2><b>Cold Storage Equipment Compared<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3050 size-large\" src=\"https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ilr-temperature-chart-1024x532.png\" alt=\"ice-lined-refrigerator-temperature\" width=\"1024\" height=\"532\" title=\"\" srcset=\"https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ilr-temperature-chart-1024x532.png 1024w, https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ilr-temperature-chart-300x156.png 300w, https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ilr-temperature-chart-768x399.png 768w, https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ilr-temperature-chart-1536x799.png 1536w, https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ilr-temperature-chart-150x78.png 150w, https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ilr-temperature-chart.png 2000w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><br \/>\n<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Equipment<\/b><\/td>\n<td><b>Purpose<\/b><\/td>\n<td><b>Typical range<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Vaccine storage refrigerator (ILR)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Vaccines, with ice-lining thermal reserve<\/span><\/td>\n<td><span style=\"font-weight: 400;\">+2\u00b0C to +8\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Laboratory refrigerator<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Reagents, media, and samples are not validated for vaccines unless stated.<\/span><\/td>\n<td><span style=\"font-weight: 400;\">+2\u00b0C to +8\u00b0C, set point varies<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Water-pack freezer<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Freezing water packs for vaccine carriers<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Model-specific, commonly below -15\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Laboratory freezer<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Samples, selected reagents<\/span><\/td>\n<td><span style=\"font-weight: 400;\">-20\u00b0C to -40\u00b0C or lower, varies by model<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Ultra low temperature freezer<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Research samples, products whose label requires it<\/span><\/td>\n<td><span style=\"font-weight: 400;\">-60\u00b0C to -86\u00b0C or lower, varies by model<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Freezer ranges are general industry values, not Bionics Scientific data. Buyers searching &#8220;ILR freezer&#8221; usually mean the water-pack freezer beside an ILR; an ILR is not a freezer. Not every mRNA vaccine needs ultra-low storage: some labels say -90\u00b0C to -60\u00b0C, others -50\u00b0C to -15\u00b0C. Follow the current product label.<\/span><\/p>\n<h2><b>ILR Vaccine Sequence: How to Load the Cabinet<\/b><\/h2>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Identify freeze-sensitive vaccines<\/b><span style=\"font-weight: 400;\">, usually including hepatitis B, DTP-containing, TT, Td, DT, inactivated polio, and HPV. Confirm on each label.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Place them in the baskets, away from walls,<\/b><span style=\"font-weight: 400;\"> clear of the ice lining and cabinet floor.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Freeze-dried vaccines<\/b><span style=\"font-weight: 400;\"> may tolerate freezing, but their diluents must never freeze.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Diluents:<\/b><span style=\"font-weight: 400;\"> store as the label states, and cool to +2\u00b0C to +8\u00b0C before reconstitution where required.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Leave air gaps,<\/b><span style=\"font-weight: 400;\"> label each basket, and use earliest-expiry stock first.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Store only vaccines,<\/b><span style=\"font-weight: 400;\"> never food, drinks, or flammable chemicals.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">An ILR suits laboratory reagents only if the product label allows +2\u00b0C to +8\u00b0C. Follow your national immunization program and manufacturer instructions.<\/span><\/p>\n<h2><b>Monitoring and Out-of-Range Action<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Read the thermometer at the start and end of each day, record minimum and maximum values, keep the probe near vaccines, calibrate on schedule, and use a data logger with an alarm for weekends.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">If a reading leaves +2\u00b0C to +8\u00b0C:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Do not discard or use the stock yet; label it &#8220;do not use&#8221; and keep it cold.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Record temperature, duration, and time found.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check VVM status; if freezing is suspected, do the shake test per national guidance.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Report to your supervisor, national program, or vaccine manufacturer for a decision.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Find the cause: power, door seal, set point, loading, or sensor.<\/span><\/li>\n<\/ol>\n<h2><b>Product Specifications: Bionics Scientific ILR Models<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Model<\/b><\/td>\n<td><b>Gross<\/b><\/td>\n<td><b>Usable (net)<\/b><\/td>\n<td><b>Ambient<\/b><\/td>\n<td><b>Holdover<\/b><\/td>\n<td><b>Freeze protection<\/b><\/td>\n<td><b>Monitoring<\/b><\/td>\n<td><b>Datasheet<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">BST-ILR64<\/span><\/td>\n<td><span style=\"font-weight: 400;\">64 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">48 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10\u00b0C to 43\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">20 to 24 h<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Data in quotation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">PT100, alarm, optional logger<\/span><\/td>\n<td><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-refrigerator\/ice-lined-refrigerator.php\"><span style=\"font-weight: 400;\">Page<\/span><\/a><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">BST-ILR136<\/span><\/td>\n<td><span style=\"font-weight: 400;\">136 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">75 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10\u00b0C to 43\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">20 to 24 h<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Data in quotation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">PT100, alarm, optional logger<\/span><\/td>\n<td><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-refrigerator\/ice-lined-refrigerator.php\"><span style=\"font-weight: 400;\">Page<\/span><\/a><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">BST-ILR218<\/span><\/td>\n<td><span style=\"font-weight: 400;\">218 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">105 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10\u00b0C to 43\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">20 to 24 h<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Data in quotation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">PT100, alarm, optional logger<\/span><\/td>\n<td><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-refrigerator\/ice-lined-refrigerator.php\"><span style=\"font-weight: 400;\">Page<\/span><\/a><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">BST-ILR235<\/span><\/td>\n<td><span style=\"font-weight: 400;\">235 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">216 L<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10\u00b0C to 43\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">20 to 24 h<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Data in quotation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">PT100, alarm, optional logger<\/span><\/td>\n<td><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-refrigerator\/ice-lined-refrigerator.php\"><span style=\"font-weight: 400;\">Page<\/span><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h6><strong>Size by usable volume, not gross volume. Holdover is the declared range across models.<\/strong><\/h6>\n<table>\n<tbody>\n<tr>\n<td><b>Parameter<\/b><\/td>\n<td><b>All models<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Dimensions (H x W x D, inches)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">33 x 28 x 27; 33 x 36 x 27; 33 x 50 x 28 (ILR218 and ILR235)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Temperature range<\/span><\/td>\n<td><span style=\"font-weight: 400;\">+2\u00b0C to +8\u00b0C (35.6\u00b0F to 46.4\u00b0F)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Controller and alarm<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Microprocessor controller, LED\/LCD display, high\/low audio-visual alarm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Optional monitoring<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Data logger, chart recorder, computer interface, door-open, sensor-fault, and condenser-fault alarms<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Construction<\/span><\/td>\n<td><span style=\"font-weight: 400;\">SS 304 interior, galvanized or CRCA exterior, PUF insulation, forced air circulation<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Cooling and defrost<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Hermetically sealed compressor; manual or automatic defrost<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Power and protection<\/span><\/td>\n<td><span style=\"font-weight: 400;\">220 \/ 240 V; high\/low voltage cut-off with time-delay restart<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Price: What Changes the Cost<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Price varies by model. It depends on usable capacity, holdover and ambient rating, power accessories such as voltage stabilizers, monitoring options, documentation, and delivery and installation.<\/span><\/p>\n<h2><b>International Availability<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Bionics Scientific welcomes inquiries worldwide. Delivery, installation, and service coverage are confirmed per destination at quotation.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ambient temperature:<\/b><span style=\"font-weight: 400;\"> compare site conditions with the 10\u00b0C to 43\u00b0C rating, especially in the Gulf states (UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain) and tropical markets such as Kenya, Ghana, and Thailand.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Electrical supply:<\/b><span style=\"font-weight: 400;\"> the listed supply is 220 \/ 240 V. The USA and Canada commonly use lower voltage at 60 Hz, so confirm the voltage and frequency.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Shipping:<\/b><span style=\"font-weight: 400;\"> Share the delivery location early for remote or inland sites.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Local compliance:<\/b><span style=\"font-weight: 400;\"> import rules and certificates differ by country.<\/span><\/li>\n<\/ul>\n<h2><b>Frequently Asked Questions<\/b><\/h2>\n<p><b>What is the correct ice-lined refrigerator temperature?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">+2\u00b0C to +8\u00b0C, or 35.6\u00b0F to 46.4\u00b0F.<\/span><\/p>\n<p><b>What does ILR stand for?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Ice-lined refrigerator, also written ILR fridge.<\/span><\/p>\n<p><b>How long does an ILR hold temperature without power?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Bionics Scientific declares 20 to 24 hours; confirm your model&#8217;s conditions.<\/span><\/p>\n<p><b>Can vaccines freeze in an ILR?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Yes, against the lining or in cold zones. Keep freeze-sensitive vaccines in baskets, away from walls.<\/span><\/p>\n<p><b>Is an ILR the same as a deep freezer?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">No. An ILR is a +2\u00b0C to +8\u00b0C refrigerator; a deep freezer stores frozen products.<\/span><\/p>\n<p><b>What is an ILR freezer?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Usually, the water-pack freezer is located next to an ILR. An ILR itself is not a freezer.<\/span><\/p>\n<p><b>Do all mRNA vaccines need ultra-low freezers?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">No. Follow the current product label.<\/span><\/p>\n<p><b>What is the best ILR thermometer setup?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A calibrated digital thermometer with minimum and maximum memory, near the vaccines, plus a daily log.<\/span><\/p>\n<p><b>What affects the ILR price?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Volume, holdover, ambient rating, monitoring, documentation, and delivery.<\/span><\/p>\n<p><b>How do I order?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Send the buyer checklist details below.<\/span><\/p>\n<h2><b>References<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><a href=\"https:\/\/extranet.who.int\/prequal\/immunization-devices\/e003-refrigerators-and-freezers\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">WHO PQS Catalogue, Category E003: Refrigerators and freezers<\/span><\/a><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><a href=\"https:\/\/www.who.int\/publications\/i\/item\/immunization-in-practice-a-practical-guide-for-health-staff\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">WHO, Immunization in Practice, Module 2: The vaccine cold chain<\/span><\/a><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><a href=\"https:\/\/www.who.int\/publications\/m\/item\/model-evm-sop-manual\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">WHO, Model EVM SOP manual<\/span><\/a><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><a href=\"https:\/\/www.cdc.gov\/vaccines\/hcp\/storage-handling\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">CDC, Vaccine Storage and Handling Toolkit<\/span><\/a><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Vaccine manufacturer package inserts and current labels<\/span><\/li>\n<\/ul>\n<h2><b>Buyer Checklist: Request a Quotation<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Send us:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Required vaccine capacity<\/b><span style=\"font-weight: 400;\"> (usable liters at peak stock)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Country<\/b><span style=\"font-weight: 400;\"> and delivery location<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ambient temperature<\/b><span style=\"font-weight: 400;\"> range at the site<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Power supply:<\/b><span style=\"font-weight: 400;\"> voltage, frequency, outage pattern<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Monitoring features:<\/b><span style=\"font-weight: 400;\"> alarm, data logger, chart recorder, or computer interface<\/span><\/li>\n<\/ol>\n<p><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"><span style=\"font-weight: 400;\">Request a quotation<\/span><\/a><span style=\"font-weight: 400;\"> or email info@bionicsscientific.com.<\/span><\/p>\n<p><b>Bionics Scientific, laboratory equipment manufacturer.<\/b><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Model evidence: Specifications come from the Bionics Scientific ILR product page. Test reports and certificates are supplied as agreed in [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3048,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[23],"tags":[],"class_list":["post-3047","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-laboratory-refrigerators"],"uagb_featured_image_src":{"full":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature.png",1000,500,false],"thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature-150x150.png",150,150,true],"medium":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature-300x150.png",300,150,true],"medium_large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature-768x384.png",768,384,true],"large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature.png",1000,500,false],"1536x1536":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature.png",1000,500,false],"2048x2048":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature.png",1000,500,false],"web-stories-poster-portrait":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature-640x500.png",640,500,true],"web-stories-publisher-logo":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature-96x96.png",96,96,true],"web-stories-thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/ice-lined-refrigerator-temperature-150x75.png",150,75,true]},"uagb_author_info":{"display_name":"Team Bionics Scientific Technologies","author_link":"https:\/\/www.bionicsscientific.com\/blogs\/author\/bionicsadmin\/"},"uagb_comment_info":0,"uagb_excerpt":"Model evidence: Specifications come from the Bionics Scientific ILR product page. Test reports and certificates are supplied as agreed in [&hellip;]","_links":{"self":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3047","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/comments?post=3047"}],"version-history":[{"count":4,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3047\/revisions"}],"predecessor-version":[{"id":3053,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3047\/revisions\/3053"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media\/3048"}],"wp:attachment":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media?parent=3047"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/categories?post=3047"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/tags?post=3047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}