{"id":3148,"date":"2026-10-23T07:24:05","date_gmt":"2026-10-23T07:24:05","guid":{"rendered":"https:\/\/www.bionicsscientific.com\/blogs\/?p=3148"},"modified":"2026-10-23T07:24:05","modified_gmt":"2026-10-23T07:24:05","slug":"blood-and-fluid-warmer","status":"publish","type":"post","link":"https:\/\/www.bionicsscientific.com\/blogs\/blood-and-fluid-warmer\/","title":{"rendered":"Blood and Fluid Warmer: A Practical Guide for Hospitals, Labs, and Buyers"},"content":{"rendered":"<h2><b>Quick Answer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A blood and fluid warmer heats blood, blood products, and IV solutions to about 37\u00b0C while they travel from the bag to the patient. Nurses and anesthetists reach for one when large amounts of cold fluid are going in fast, since that is the situation where body temperature slips.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">You will see three names used for this equipment:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Blood transfusion warmer, when the fluid is a blood component<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">IV fluid warmer, when the fluid is saline or another IV solution<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Medical fluid warmer, a general name for both<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">In many cases it is one device doing both jobs. The instructions for use tell you which fluids your model is cleared for, which disposable set goes with it, and what flow range it supports.<\/span><\/p>\n<h2><b>Why Cold Fluids Cause Trouble<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Blood banks keep red cells cold, usually around 1\u00b0C to 6\u00b0C. One unit of cold blood is rarely a problem. Several units in a short stretch, say in a long operation or after a serious accident, can pull the core temperature down. Hospital transfusion guidelines connect this with hypothermia and irregular heartbeat, and newborns are the most vulnerable.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Too much heat does damage as well. Red cells suffer when overheated, and AABB guidance sets 42\u00b0C as the ceiling for warmed blood products. The same guidance expects a warmer to display its temperature and warn staff when something fails. The<\/span><a href=\"https:\/\/healthproviders.sharedhealthmb.ca\/files\/blood-warming-devices.pdf\" target=\"_blank\" rel=\"noopener\"> <span style=\"font-weight: 400;\">Shared Health Manitoba blood warming guidelines<\/span><\/a><span style=\"font-weight: 400;\"> show how one hospital system puts this into practice.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">If your blood bank stores units in a<\/span><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-refrigerator\/\"> <span style=\"font-weight: 400;\">laboratory refrigerator<\/span><\/a><span style=\"font-weight: 400;\">, the warmer is the step that takes them from storage temperature to something the patient can safely receive.<\/span><\/p>\n<h2><b>How It Works<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Fluid leaves the bag and runs through a disposable set, either a length of tubing or a flat cassette, that touches a heated surface. A sensor reports the temperature to a controller. The controller turns heat up or down to stay close to the target, and an alarm sounds if the reading leaves its allowed range.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Flow rate is what makes this tricky. Fast flow leaves little time to transfer heat, so the fluid may come out cooler than intended. Slow flow, or a bag that is nearly empty, lets the same heat push the temperature higher. This is why sensor position and control software matter more than how powerful the heater is. A well-designed unit keeps the outlet steady whether the infusion is slow or fast.<\/span><\/p>\n<h2><b>Types of Blood and Fluid Warmers<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Most warmers can be sorted by how they heat and by who they are made for.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Dry-heat warmers use a heated plate or sleeve. They are usually compact and clip onto an IV pole. Water-based warmers circulate warm water around the fluid path and are often picked for even heat transfer.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">On the patient side, standard models cover everyday infusion, high-flow models are designed for rapid transfusion, and pediatric models use smaller sets for low volumes.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A common question is whether a blood warmer and an IV fluid warmer are really different. Usually they are not. Makers often describe a single device for blood, blood products, and IV solutions, and the real differences between models are the set, the flow range, and the temperature limit set by the maker. Platelets are normally not warmed, so check your blood bank policy.<\/span><\/p>\n<h2><b>Where Warmers Are Used<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Major surgery with heavy blood or fluid loss<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Trauma care and emergency resuscitation<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Intensive care units<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pediatric and neonatal transfusion, including exchange transfusion<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Any case where the team wants to protect the patient&#8217;s temperature during infusion<\/span><\/li>\n<\/ul>\n<h2><b>Advantages<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Helps keep the patient&#8217;s temperature steady during infusion<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Shows staff a live temperature reading and sounds an alarm when needed<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Uses single-patient disposable sets, so the fluid path is not shared between patients<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Can be mounted on an IV pole or placed at the bedside in a few seconds<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Works with both blood products and IV solutions on models rated for both<\/span><\/li>\n<\/ul>\n<h2><b>Blood and Fluid Warmer Specifications<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Specifications differ by model and intended use. Contact Bionics Scientific to confirm available features and technical details before you buy.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Parameter<\/b><\/td>\n<td><b>What to Check<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Heating method<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Dry heat or water-based<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Temperature control<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Operating range and settings<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Accuracy<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Documented temperature accuracy<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Flow rate<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Supported flow range<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Warm-up time<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Time to reach operating temperature<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Safety features<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Temperature alarms and protective cut-off<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Display<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Temperature readings and status<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Accessories<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Compatible tubing and disposable sets<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Power supply<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Voltage and frequency<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Maintenance<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Cleaning and servicing requirements<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Documentation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Technical specifications and applicable certifications<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Confirm model-specific specifications, accessories, and documentation with Bionics Scientific before ordering.<\/span><\/p>\n<h2><b>Temperature Reference<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Treat this as a general guide. The manufacturer&#8217;s instructions for use decide the final setting.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Fluid<\/b><\/td>\n<td><b>Typical Target at Outlet<\/b><\/td>\n<td><b>Upper Limit<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Packed red blood cells<\/span><\/td>\n<td><span style=\"font-weight: 400;\">About 37\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">As per manufacturer instructions, AABB guidance is 42\u00b0C for blood products.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Crystalloid IV solutions<\/span><\/td>\n<td><span style=\"font-weight: 400;\">About 37\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">As per manufacturer instructions<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Platelets<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Do not warm.<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Follow your blood bank policy.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">A warmer supports clinical care and never replaces it. Follow your hospital protocol and the device manual.<\/span><\/p>\n<h2><b>Buying Guide: 15 Points to Check<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Hospitals and operating theaters should look at:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Outlet temperature accuracy<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A clear, visible temperature display<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Over-temperature and malfunction alarms<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Maximum flow rate for their usual cases<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Time needed before the unit is ready<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">Laboratories and biomedical teams should look at:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Calibration method and certificate<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cleaning instructions and surface material<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Weight and pole clamp design<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Manual, test report, and warranty terms<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Availability of disposable sets<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">Distributors and procurement teams should look at:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Power supply for the destination country<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Regulatory requirements in their market<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Yearly cost of disposable sets<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Service and support response time<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Total cost, including shipping and duty<\/span><\/li>\n<\/ol>\n<h2><b>About Bionics Scientific<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Bionics Scientific has<\/span><a href=\"https:\/\/www.bionicsscientific.com\/about-us.php\"> <span style=\"font-weight: 400;\">35 years of experience<\/span><\/a><span style=\"font-weight: 400;\"> manufacturing laboratory equipment in India. Tell us your flow rate, temperature range, and set type, and our team will help you pick a suitable model and share its datasheet so you can check it against your hospital protocol before ordering.<\/span><\/p>\n<h2><b>Where We Receive Enquiries From<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Our inquiries come from the United States (USA), the United Kingdom (UK), the United Arab Emirates (UAE), Saudi Arabia, South Africa, Canada, Australia, Singapore, Malaysia, Philippines, Indonesia, Kenya, Bangladesh, Nepal, Qatar, Oman, Kuwait, Bahrain, Vietnam, Thailand, Tanzania, Ghana, Sri Lanka, and New Zealand. We confirm delivery options, voltage, and plug type on the quotation for your country.<\/span><\/p>\n<h2><b>Frequently Asked Questions<\/b><\/h2>\n<p><b>What is a blood and fluid warmer?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A device that warms blood, blood products, and IV solutions to about 37\u00b0C before infusion.<\/span><\/p>\n<p><b>Is a blood transfusion warmer different from an IV fluid warmer?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Often it is the same device. The manual lists the fluids each model supports.<\/span><\/p>\n<p><b>What temperature should warmed blood reach?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">About 37\u00b0C at the outlet, within the maker&#8217;s limit. AABB guidance caps blood products at 42\u00b0C.<\/span><\/p>\n<p><b>What flow rate can a warmer handle?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">It depends on the model and set. Check the maximum flow rate on the datasheet.<\/span><\/p>\n<p><b>How long does it take to heat up?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">It varies by model. The datasheet states the warm-up time.<\/span><\/p>\n<p><b>Which safety alarms should it have?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A visible temperature display and alarms for over-temperature and malfunction.<\/span><\/p>\n<p><b>How often does it need calibration?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Follow the manual and your biomedical team&#8217;s schedule.<\/span><\/p>\n<p><b>What maintenance does it need?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Clean it as per policy, inspect cords and sensors, and use a fresh disposable set as directed.<\/span><\/p>\n<p><b>How much does a blood and fluid warmer cost?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Price depends on model, flow range, and set type. Send your requirement for a quotation.<\/span><\/p>\n<p><b>How do I request a quotation?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Share your product model, required flow rate, temperature range, and delivery country.<\/span><\/p>\n<h2><b>Get Your Quotation Today<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Send the Bionics Scientific team your product model, required flow rate, temperature range, and delivery country.<\/span><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"> <b>Request a quote now<\/b><\/a><span style=\"font-weight: 400;\"> and we will reply with the datasheet, pricing, and lead time.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Quick Answer A blood and fluid warmer heats blood, blood products, and IV solutions to about 37\u00b0C while they travel [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3149,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[61],"tags":[],"class_list":["post-3148","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-misc"],"uagb_featured_image_src":{"full":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer.png",1000,500,false],"thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer-150x150.png",150,150,true],"medium":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer-300x150.png",300,150,true],"medium_large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer-768x384.png",768,384,true],"large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer.png",1000,500,false],"1536x1536":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer.png",1000,500,false],"2048x2048":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer.png",1000,500,false],"web-stories-poster-portrait":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer-640x500.png",640,500,true],"web-stories-publisher-logo":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer-96x96.png",96,96,true],"web-stories-thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/10\/blood-and-fluid-warmer-150x75.png",150,75,true]},"uagb_author_info":{"display_name":"Team Bionics Scientific Technologies","author_link":"https:\/\/www.bionicsscientific.com\/blogs\/author\/bionicsadmin\/"},"uagb_comment_info":0,"uagb_excerpt":"Quick Answer A blood and fluid warmer heats blood, blood products, and IV solutions to about 37\u00b0C while they travel [&hellip;]","_links":{"self":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3148","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/comments?post=3148"}],"version-history":[{"count":1,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3148\/revisions"}],"predecessor-version":[{"id":3150,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3148\/revisions\/3150"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media\/3149"}],"wp:attachment":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media?parent=3148"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/categories?post=3148"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/tags?post=3148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}