{"id":3194,"date":"2026-11-10T06:14:56","date_gmt":"2026-11-10T06:14:56","guid":{"rendered":"https:\/\/www.bionicsscientific.com\/blogs\/?p=3194"},"modified":"2026-11-10T06:14:56","modified_gmt":"2026-11-10T06:14:56","slug":"probe-sonicator","status":"publish","type":"post","link":"https:\/\/www.bionicsscientific.com\/blogs\/probe-sonicator\/","title":{"rendered":"Probe Sonicator: Working, Specifications, and Buying Guide for Labs Across the Middle East, Asia-Pacific, and Africa"},"content":{"rendered":"<h2><b>Quick Answer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A <\/span><b>probe sonicator<\/b><span style=\"font-weight: 400;\"> is a laboratory device that pushes high-frequency sound waves (usually 20 kHz) straight into a liquid through a titanium probe. The sound creates millions of tiny bubbles that collapse violently, and that collapse breaks cells, disperses particles, and mixes emulsions.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What is ultrasonicator:<\/b><span style=\"font-weight: 400;\"> a machine that turns electrical energy into ultrasonic vibration.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ultrasonic probe sonicator:<\/b><span style=\"font-weight: 400;\"> the direct-contact type, far stronger than a bath.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ultrasonic sonicator:<\/b><span style=\"font-weight: 400;\"> the general name for both probe and bath models.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ultrasonic sterilization:<\/b><span style=\"font-weight: 400;\"> useful for disrupting microbes and cleaning, but not a replacement for an autoclave.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Best for:<\/b><span style=\"font-weight: 400;\"> cell lysis, nanoparticle dispersion, emulsification, degassing, and DNA shearing.<\/span><\/li>\n<\/ul>\n<h2><b>What Is an Ultrasonicator?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">If you are asking what an ultrasonicator is, think of it as a controlled source of vibration. A generator converts mains power into a 20 kHz electrical signal. A piezoelectric converter changes that signal into mechanical movement. A horn, or probe, then moves up and down a few microns, thousands of times per second, inside your sample.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Bionics Scientific has manufactured laboratory equipment for 26 years, and in that time the questions we hear most are simple ones: how much power do I need, and why did my sample get hot? This guide answers both.<\/span><\/p>\n<h2><b>How a Probe Sonicator Works<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The process is called acoustic cavitation. The probe tip pushes and pulls on the liquid. During the pull phase, tiny vacuum bubbles form. During the push phase they implode, creating local pressure spikes and shear forces strong enough to tear cell walls apart. A deeper explanation of sonication is available on<\/span><a href=\"https:\/\/en.wikipedia.org\/wiki\/Sonication\" target=\"_blank\" rel=\"noopener\"> <span style=\"font-weight: 400;\">Wikipedia&#8217;s sonication page<\/span><\/a><span style=\"font-weight: 400;\">.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Three settings control the result:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Amplitude:<\/b><span style=\"font-weight: 400;\"> how far the tip travels, shown as a percentage.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Pulse ratio:<\/b><span style=\"font-weight: 400;\"> seconds on versus seconds off.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Time:<\/b><span style=\"font-weight: 400;\"> total processing duration.<\/span><\/li>\n<\/ol>\n<h2><b>Probe Sonicator vs Ultrasonic Bath<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An ultrasonic bath sends waves through a water tank and then through the sample vessel wall, so much of the energy is lost. A probe delivers it directly. For stubborn jobs such as yeast, spores, or nanoparticle clusters, a bath rarely works. For routine cleaning of glassware, a bath is fine and cheaper.<\/span><\/p>\n<h2><b>Ultrasonic Sterilization: What It Can and Cannot Do<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Ultrasonic sterilization is a phrase many buyers search, so let us be accurate. Cavitation can kill or rupture bacteria, reduce biofilm, and disrupt cell membranes. It is widely used for decontaminating instruments before sterilization and for lowering microbial load in liquids. However, ultrasound alone does not meet the validated sterility standard of a steam<\/span><a href=\"https:\/\/www.bionicsscientific.com\/autoclave-sterilizer\/\"> <span style=\"font-weight: 400;\">autoclave<\/span><\/a><span style=\"font-weight: 400;\">. If your protocol demands sterility assurance, use ultrasound as a pre-treatment and finish with a validated method.<\/span><\/p>\n<h2><b>Where Labs Use a Probe Sonicator<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cell disruption for protein and enzyme extraction<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">DNA and chromatin shearing for sequencing prep<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Nanoparticle and graphene dispersion<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Nanoemulsions in pharma, cosmetics, and food research<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Liposome size reduction<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Degassing solvents and HPLC mobile phases<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Homogenizing tissue samples<\/span><\/li>\n<\/ul>\n<h2><b>Specification Table<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Parameter<\/b><\/td>\n<td><b>Typical Range (Bionics Scientific Models)<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Frequency<\/span><\/td>\n<td><span style=\"font-weight: 400;\">20 kHz \u00b1 0.5 kHz<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Power output<\/span><\/td>\n<td><span style=\"font-weight: 400;\">100 W, 250 W, 500 W, 750 W, 1000 W, 1500 W<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Sample volume<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.1 mL to 1000 mL (probe dependent)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Probe material<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Titanium alloy (Ti-6Al-4V)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Probe diameters<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3 mm, 6 mm, 13 mm, 19 mm, 25 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Amplitude control<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10% to 100%, adjustable<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Pulse mode<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1 to 99 seconds on\/off<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Timer<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Up to 99 minutes<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Display<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Digital LCD with real-time power reading<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Protection<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Overload, overheating, and probe-fault cut-off<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Enclosure<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Optional sound-proof chamber<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Power supply<\/span><\/td>\n<td><span style=\"font-weight: 400;\">220\u2013240 V, 50\/60 Hz (110 V on request)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Temperature probe<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Optional, with auto-stop<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Temperature Chart: Why Heat Matters<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Cavitation turns part of the energy into heat. Without cooling, a 50 mL sample at 60% amplitude can climb past 50 \u00b0C within minutes, which denatures proteins and degrades RNA. The values below are indicative figures for a 500 W unit, 13 mm probe, 50 mL water sample, starting at 4\u00b0C.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Run Time<\/b><\/td>\n<td><b>Continuous, No Ice<\/b><\/td>\n<td><b>Continuous Ice Bath<\/b><\/td>\n<td><b>Pulse 5s On\/5s Off, Ice Bath<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">1 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">18 \u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">6 \u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">5 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">3 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">38 \u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">9 \u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">6 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">5 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">56 \u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">13 \u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">8 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">10 min<\/span><\/td>\n<td><span style=\"font-weight: 400;\">78 \u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">21 \u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400;\">11 \u00b0C<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Probe sonicator temperature rise chart showing continuous run without ice, continuous run in ice bath, and pulse mode in ice bath<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Practical rule: use pulse mode, keep the vessel in an ice-salt bath, and let the sample rest between cycles.<\/span><\/p>\n<h2><b>15 Things Buyers Actually Think About<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Buyers in our regions rarely ask only about price. These are the points that come up in real purchase discussions:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Power rating:<\/b><span style=\"font-weight: 400;\"> match watts to sample volume, not to a higher number.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Probe size:<\/b><span style=\"font-weight: 400;\"> small tips for microliter work, large tips for liters.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Heat control:<\/b><span style=\"font-weight: 400;\"> look for a built-in temperature sensor.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Probe life:<\/b><span style=\"font-weight: 400;\"> titanium tips erode, so ask about replacement cost.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Noise:<\/b><span style=\"font-weight: 400;\"> a soundproof enclosure protects operators.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Pulse flexibility:<\/b><span style=\"font-weight: 400;\"> needed for heat-sensitive biologicals.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Repeatability:<\/b><span style=\"font-weight: 400;\"> consistent amplitude batch after batch.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Safety cut-offs:<\/b><span style=\"font-weight: 400;\"> protection against dry running.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Calibration:<\/b><span style=\"font-weight: 400;\"> traceable documentation for audits.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Warranty:<\/b><span style=\"font-weight: 400;\"> length and what is covered.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Spare parts:<\/b><span style=\"font-weight: 400;\"> local stock, not a six-week wait.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Voltage compatibility:<\/b><span style=\"font-weight: 400;\"> 220 V versus 110 V.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Installation and training:<\/b><span style=\"font-weight: 400;\"> especially for new labs.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Export paperwork:<\/b><span style=\"font-weight: 400;\"> invoices, packing list, conformity papers.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>After-sales response time:<\/b><span style=\"font-weight: 400;\"> a quick reply matters more than a long brochure.<\/span><\/li>\n<\/ol>\n<h2><b>Supply Across the Middle East, Asia-Pacific, and Africa<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Our priority market is the <\/span><b>Middle East<\/b><span style=\"font-weight: 400;\">. We supply universities, hospitals, petrochemical labs, and food-testing units in the <\/span><b>United Arab Emirates (UAE), Saudi Arabia, Qatar, Oman, Kuwait, and Bahrain<\/b><span style=\"font-weight: 400;\">, where high ambient temperatures make cooling and heat-protection features especially important. In Asia-Pacific we ship to <\/span><b>Australia, Singapore, Malaysia, the Philippines, Indonesia, Vietnam, Bangladesh, and Nepal<\/b><span style=\"font-weight: 400;\">, and in Africa to <\/span><b>Kenya<\/b><span style=\"font-weight: 400;\">. Voltage, plug type, and documentation are adjusted for each destination.<\/span><\/p>\n<h2><b>Why Choose Bionics Scientific<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">35 years of laboratory equipment manufacturing experience<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">In-house design, assembly, and testing, with no third-party rebranding<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Each unit is output-tested before dispatch<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Custom probes and enclosures available<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Technical support from engineers who built the machine<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Alongside sonicators, we also build<\/span><a href=\"https:\/\/www.bionicsscientific.com\/laboratory-mixers\/\"> <span style=\"font-weight: 400;\">laboratory mixers<\/span><\/a><span style=\"font-weight: 400;\"> for gentler blending work.<\/span><\/p>\n<h2><b>Frequently Asked Questions<\/b><\/h2>\n<p><b>What is a probe sonicator used for?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Cell lysis, nanoparticle dispersion, emulsification, and DNA shearing.<\/span><\/p>\n<p><b>What is an ultrasonicator?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A machine that creates ultrasonic vibrations to disrupt or mix samples.<\/span><\/p>\n<p><b>How is a probe sonicator different from a bath?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A probe touches the sample directly, so it delivers much more energy.<\/span><\/p>\n<p><b>What frequency do probe sonicators use?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Most operate at 20 kHz.<\/span><\/p>\n<p><b>Can ultrasonic sterilization replace an autoclave?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">No. It reduces microbes but does not guarantee sterility.<\/span><\/p>\n<p><b>How do I stop my sample overheating?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Use pulse mode and an ice bath.<\/span><\/p>\n<p><b>Which probe size should I choose?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Small probes for small volumes, larger probes for bigger batches.<\/span><\/p>\n<p><b>How long does a titanium probe last?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Typically several hundred hours, depending on amplitude and sample.<\/span><\/p>\n<p><b>Do you ship to the Middle East?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Yes, to the UAE, Saudi Arabia, Qatar, Oman, Kuwait, and Bahrain.<\/span><\/p>\n<p><b>Can you customize a probe sonicator?<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Yes, power, probes, and enclosures can be tailored.<\/span><\/p>\n<h2><b>Get Your Probe Sonicator Quote Today<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Stop guessing which sonicator fits your sample. Tell our engineers your volume, material, and target region, and we will recommend the exact model, probe, and cooling setup, with a clear quotation and delivery timeline.<\/span><a href=\"https:\/\/www.bionicsscientific.com\/contact-us.php\"> <span style=\"font-weight: 400;\">Contact Bionics Scientific now<\/span><\/a><span style=\"font-weight: 400;\"> and get your lab running faster.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Quick Answer A probe sonicator is a laboratory device that pushes high-frequency sound waves (usually 20 kHz) straight into a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3195,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[61],"tags":[],"class_list":["post-3194","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-misc"],"uagb_featured_image_src":{"full":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator.png",1000,500,false],"thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator-150x150.png",150,150,true],"medium":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator-300x150.png",300,150,true],"medium_large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator-768x384.png",768,384,true],"large":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator.png",1000,500,false],"1536x1536":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator.png",1000,500,false],"2048x2048":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator.png",1000,500,false],"web-stories-poster-portrait":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator-640x500.png",640,500,true],"web-stories-publisher-logo":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator-96x96.png",96,96,true],"web-stories-thumbnail":["https:\/\/www.bionicsscientific.com\/blogs\/wp-content\/uploads\/2026\/11\/probe-sonicator-150x75.png",150,75,true]},"uagb_author_info":{"display_name":"Team Bionics Scientific Technologies","author_link":"https:\/\/www.bionicsscientific.com\/blogs\/author\/bionicsadmin\/"},"uagb_comment_info":0,"uagb_excerpt":"Quick Answer A probe sonicator is a laboratory device that pushes high-frequency sound waves (usually 20 kHz) straight into a [&hellip;]","_links":{"self":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/comments?post=3194"}],"version-history":[{"count":1,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3194\/revisions"}],"predecessor-version":[{"id":3196,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/posts\/3194\/revisions\/3196"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media\/3195"}],"wp:attachment":[{"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/media?parent=3194"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/categories?post=3194"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bionicsscientific.com\/blogs\/wp-json\/wp\/v2\/tags?post=3194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}