Bionics Scientific manufactures clean room ovens for controlled heating, drying and thermal processing in pharmaceutical, research and industrial laboratory environments. These cleanroom cabinet ovens are available with configurable airflow arrangements, including vertical or horizontal airflow, and optional HEPA filter modules depending on the required application.
Models are available for Class 100 and Class 1000 applications as specified in the product range. The actual cleanroom classification of a configured oven should be confirmed through appropriate particle-count testing under defined operating conditions. Options such as nitrogen gas purging and vacuum ports can also be discussed according to process requirements.
| Suitable for Class 100 and Class 1000 applications, subject to configuration and validation | Temperature range: Ambient +10°C to +200°C |
| Stainless steel interior chamber for easy cleaning | Designed for controlled laboratory heating and drying |
| Optional HEPA filter modules for particulate filtration | Digital temperature display and microprocessor controller |
| Configured vertical or horizontal airflow options | Over-temperature protection for operational safety |
| Optional nitrogen gas purging connection | Factory assembled and tested before dispatch |
Construction: Our clean room ovens are designed with an exterior made of powder-coated mild steel and an interior chamber made of 304-grade stainless steel. Stainless steel construction options can be discussed based on application and material requirements.
Temperature: Our clean room ovens offer a temperature range of ambient +10°C to +200°C, making them suitable for controlled heating and drying applications in laboratory environments.
Controls: Our standard clean room ovens are equipped with a digital temperature controller and timer. Operators can set the required temperature and operating time through the control panel. The heating cycle is controlled according to the selected settings.
Door: Depending on the chamber size and model, our clean room ovens are available with single-door or double-door configurations. The insulated doors are fitted with sturdy handles and secure locking arrangements to help maintain stable operating conditions. An optional door limit switch can be provided to stop the heating operation when the door is opened.
Filter: Our clean room ovens are available with optional HEPA filter modules, depending on the model and application requirements. HEPA filtration helps reduce airborne particulate contamination within the oven chamber. The achievable cleanliness level depends on the oven configuration, airflow design, filter efficiency and operating conditions. Cleanroom classification should be confirmed through appropriate particle-count testing under defined operating conditions.
Optional Accessories: Bionics Scientific offers customization options for clean room ovens based on specific application and process requirements. Available options may include programmable controllers, heating element configurations, material of construction (MOC) choices, nitrogen gas inlet ports and vacuum connections. Additional accessories can be discussed during the specification and quotation process.
| Model | BST/CRO-072 | BST/CRO-270 | BST/CRO-480 | BST/CRO-600 | BST/CRO-720 |
|---|---|---|---|---|---|
| Inner chamber WxHxD (mm) | 450x400x400 | 600x900x500 | 800x1000x600 | 1000x1000x600 | 1200x1000x600 |
| Exterior chamber WxHxD (mm) | 870x1200x550 | 1050x1650x740 | 1200x1700x840 | 1400x1750x840 | 1750x1750x840 |
| Temperature | Range: Ambient +10°C to +200°C Accuracy: ±0.3°C Uniformity: ±1°C Resolution: 0.1°C |
||||
| Cleanroom Classification | Class 100 / Class 1000 applications, subject to model configuration and particle-count validation | ||||
| Construction | Exterior Chamber: Powder Coated MS Interior Chamber: 304 stainless steel plate Insulation: PU & Fiberglass wool |
||||
| Filtration | Optional HEPA filter modules, depending on model configuration | ||||
| Air Circulation | Fan or Re-circulating Blower | ||||
| Heating Element | Kanthal A1 Wire | ||||
| Door | Insulated solid door with silicon rubber seal | ||||
| Controller | Programmable Temperature and Time Controller | ||||
| Shelves | Nickel Chrome Plated Steel Wire Shelves | ||||
| Safety Devices | - Overheating circuit-breaker - Compressor overload protection - Control system overload protection - Breakdown indicator light |
||||
|
Optional |
- Stainless Steel Exterior - Humidifying system - Nitrogen inlet port - Differential air pressure switch - Door limit switch - Chart recorder - Pressure gauge - Stainless Steel shelves - Perforated SS Shelves |
||||
| Power supply | 220V 50Hz | ||||
Looking for a clean room oven manufacturer in India? Contact Bionics Scientific for product specifications, available configurations, pricing and delivery details. Submit your enquiry through the form to discuss your laboratory heating and cleanroom requirements with our team.
A clean room oven is used for controlled heating and drying applications in laboratory, pharmaceutical and industrial environments where airborne particulate contamination needs to be managed.
Bionics Scientific clean room ovens offer a temperature range from ambient +10°C to +200°C. The specified temperature range supports different laboratory heating and drying requirements.
Class 100 and Class 1000 refer to different levels of airborne particle cleanliness. The suitable classification for an oven depends on its configuration, airflow design, filtration and particle-count validation under defined operating conditions.
HEPA filtration may be required when an application needs control of airborne particles. Bionics Scientific offers optional HEPA filter modules depending on the oven model and application requirements.
The listed construction includes a powder-coated mild steel exterior and a 304-grade stainless steel interior chamber. Stainless steel exterior options can also be discussed according to application requirements.
Yes. Available customization options may include nitrogen gas inlet ports, vacuum connections, programmable controllers and material-of-construction choices, depending on the required configuration.
The listed safety features include an overheating circuit-breaker, compressor overload protection, control system overload protection and a breakdown indicator light.
Contact Bionics Scientific with your required chamber dimensions, operating temperature and application details to request product specifications, available configurations and pricing.

May this festival of lights bring happiness, prosperity and success to you and your organization. Wishing you brighter ideas, new opportunities and continued growth.