Trade Mark No.: 2022609
A Kjeldahl apparatus is used for determining nitrogen content and estimating protein in laboratory samples using the Kjeldahl method. These systems are commonly used in food, dairy, fertilizer, chemical, pharmaceutical and research laboratories.
Bionics Scientific manufactures space-saving Kjeldahl Digestion and Distillation Units with combined digestion and distillation functionality. These systems are available in 3-test and 6-test models with mantle type heating units. Each heater is fitted with an individual energy regulator for better control and consistent performance.
The standard units feature a powder-coated MS construction and accommodate 300 ml and 500 ml flasks. Optional accessories such as glassware, clamps, lead fume duct and condenser rack are available according to the selected configuration and laboratory requirements.
| Available in 3 and 6 test units | Mantle type heaters |
| Accommodates 300 ml and 500 ml flasks | Individual heating control for each test position |
| Ideal for nitrogen and protein analysis | Supplied with or without glass parts |
| Adjustable clamps | Individual energy regulators |
| Durable MS powder coated cabinet | Open or hooded combination type |
| Model | BST/KDU-3 | BST/KDU-6 |
|---|---|---|
| Number of Test Positions | 3 test | 6 test |
| Heater | Mantle type | |
| Flask Capacities | 300 ml / 500 ml | |
| Maximum Temperature | 350°C | |
| Heater Rating | 200 watts | |
| Construction | MS powder coated | |
| Optional Accessories | Glassware, clamps, lead fume duct, condenser rack | |
| Power Supply | 220 Volts 50Hz | |
| Product | Micro Kjeldahl Digestion Distillation Unit |
|---|---|
| Construction | 304 Grade Stainless Steel |
| Flasks | 30 ml, 50 ml and 100 ml |
| Heating Element | Kanthal A-1 |
| Heater Watt | 200 Watt |
| Max. Temperature | 350°C |
| Lead Fume Duct | Optional |
| Power Supply | 220 Volts |
Share your required number of tests, flask capacity and laboratory application to receive suitable model details, technical specifications and current pricing.
Request a QuoteBionics Scientific supplies Kjeldahl digestion and distillation units in multiple configurations for laboratory nitrogen and protein analysis. Standard options include 3-test and 6-test models, with micro Kjeldahl configurations available for smaller sample volumes.
Model selection can be based on the required number of tests, flask capacity, heating configuration, construction and optional accessories. Final specifications should be selected according to the laboratory application and sample requirements.
The Micro Kjeldahl Digestion and Distillation Unit is designed for laboratory applications requiring nitrogen and protein analysis with smaller sample volumes. Available flask capacities include 30 ml, 50 ml and 100 ml, depending on the selected configuration.
The unit uses individually controlled heating for the digestion process. Construction, heating configuration and optional accessories should be selected according to the required laboratory application and model specifications.
Bionics Scientific also manufactures Water Distillers for laboratories. Visit our Contact Us page to discuss your laboratory equipment requirements and request a quotation.
.kj-faq { margin: 25px 0; } .kj-faq .faq-item { border: 1px solid #dddddd; border-radius: 3px; margin-bottom: 8px; background: #ffffff; overflow: hidden; } .kj-faq .faq-question { width: 100%; border: 0; background: #f7f7f7; padding: 11px 14px; font-size: 14px; line-height: 1.5; font-weight: 600; text-align: left; cursor: pointer; display: flex; justify-content: space-between; align-items: center; } .kj-faq .faq-icon { font-size: 18px; font-weight: 500; margin-left: 10px; } .kj-faq .faq-answer { display: none; padding: 11px 14px; border-top: 1px solid #eeeeee; } .kj-faq .faq-answer p { margin: 0; font-size: 13px; line-height: 1.7; } .kj-faq .faq-item.active .faq-answer { display: block; }A Kjeldahl digestion and distillation unit is laboratory equipment used in the Kjeldahl method for nitrogen determination and protein estimation in different types of samples.
Digestion converts nitrogen present in the sample into an ammonium form using suitable reagents and heating. The distillation stage is then used as part of the subsequent nitrogen determination process.
Yes. Standard Kjeldahl digestion units are available in 3-test and 6-test configurations, allowing laboratories to select a model according to their sample testing requirements.
The standard models support 300 ml and 500 ml flasks. Micro Kjeldahl configurations are available with smaller flask capacities such as 30 ml, 50 ml and 100 ml.
The listed Kjeldahl digestion unit models have a maximum temperature specification of 350°C. Individual energy regulators are provided for heating control.
A Micro Kjeldahl unit is intended for laboratory applications requiring nitrogen determination and protein estimation with smaller sample volumes.
Kjeldahl units are used in food and dairy testing, fertilizer and agricultural testing, chemical and pharmaceutical laboratories, environmental testing, research institutions and quality control laboratories.
Model selection should consider the number of test positions, required flask capacity, heating configuration, sample volume, construction and optional accessories required for the laboratory application.