A Kjeldahl digestion unit is the heating part of Kjeldahl nitrogen analysis. It heats a sample with concentrated acid until the nitrogen in it turns into ammonium, ready for distillation and titration. Every test position has its own heater, so you can digest a batch of samples side by side.
Bionics Scientific manufactures space-saving Kjeldahl Digestion and Distillation Units with combined digestion and distillation functionality, in 3-test (BST/KDU-3) and 6-test (BST/KDU-6) models. They use mantle type heaters, each with its own energy regulator, a powder-coated MS cabinet, and take 300 ml and 500 ml flasks. The listed maximum temperature is 350°C and the supply is 220 V. Glassware, clamps, lead fume duct and condenser rack are optional. We have been manufacturing laboratory equipment in India for 26 years.
Need a price or a model recommendation? Tell us your number of tests, flask size and application. Call +91-9111161955 or send an enquiry.
Get a QuoteThe factor depends on the sample: 6.25 is widely used for food and feed, 6.38 for dairy and 5.70 for wheat flour. Kjeldahl measures nitrogen, not protein directly, so your protein figure is only as good as the factor you choose. Water and wastewater labs use the same method to report total Kjeldahl nitrogen (TKN). For an overview, see the Kjeldahl method article on Wikipedia.
The specifications below describe the digestion heaters, flasks and construction. If you need a full setup with distillation glassware and a condenser rack, tell us when you enquire and we will confirm the arrangement in your quotation.
| Available in 3 and 6 test units | Mantle type heaters |
| Accommodates 300 ml and 500 ml flasks | Individual heating control for each test position |
| Ideal for nitrogen and protein analysis | Supplied with or without glass parts |
| Adjustable clamps | Individual energy regulators |
| Durable MS powder coated cabinet | Open or hooded combination type |
| Model | BST/KDU-3 | BST/KDU-6 |
|---|---|---|
| Number of Test Positions | 3 test | 6 test |
| Heater | Mantle type | |
| Flask Capacities | 300 ml / 500 ml | |
| Maximum Temperature | 350°C | |
| Heater Rating | 200 watts | |
| Construction | MS powder coated | |
| Optional Accessories | Glassware, clamps, lead fume duct, condenser rack | |
| Power Supply | 220 Volts 50Hz | |
| Product | Micro Kjeldahl Digestion Distillation Unit |
|---|---|
| Construction | 304 Grade Stainless Steel |
| Flasks | 30 ml, 50 ml and 100 ml |
| Heating Element | Kanthal A-1 |
| Heater Watt | 200 Watt |
| Max. Temperature | 350°C |
| Lead Fume Duct | Optional |
| Power Supply | 220 Volts |
Share your required number of tests, flask capacity and laboratory application to receive suitable model details, technical specifications and current pricing.
Request a QuoteBionics Scientific supplies Kjeldahl digestion and distillation units in multiple configurations for laboratory nitrogen and protein analysis. Standard options include 3-test and 6-test models, with micro Kjeldahl configurations available for smaller sample volumes.
Model selection can be based on the required number of tests, flask capacity, heating configuration, construction and optional accessories. Final specifications should be selected according to the laboratory application and sample requirements.
The Micro Kjeldahl Digestion and Distillation Unit is designed for laboratory applications requiring nitrogen and protein analysis with smaller sample volumes. Available flask capacities include 30 ml, 50 ml and 100 ml, depending on the selected configuration.
The unit uses individually controlled heating for the digestion process. Construction, heating configuration and optional accessories should be selected according to the required laboratory application and model specifications.
| Your situation | Choose |
|---|---|
| Small batches, up to 3 samples at a time | BST/KDU-3 (3 test) |
| Larger batches or higher daily throughput | BST/KDU-6 (6 test) |
| Very small sample volumes | Micro Kjeldahl unit (30, 50 or 100 ml flasks) |
| You already have a fume hood | Open type |
| No fume hood or scrubber | Hooded type with lead fume duct |
| You already own flasks and condensers | Unit without glass parts |
Check the digestion temperature in your own test method against the listed 350°C maximum, and tell us if you are unsure.
The price depends on the number of tests, macro or micro configuration, construction material, glassware and any optional accessories. Two laboratories asking for the same model often need different accessories, so we quote for your exact requirement and do not publish a single price.
Send your requirement or call +91-9111161955. You can also read more about Bionics Scientific.
Bionics Scientific also manufactures Water Distillers for laboratories. Visit our Contact Us page to discuss your laboratory equipment requirements and request a quotation.
For fat or oil determination alongside nitrogen analysis, see our Soxhlet extraction unit.
Learn more about the Kjeldahl assembly and its working principle to understand the digestion, distillation and nitrogen analysis process.
A Kjeldahl digestion and distillation unit is laboratory equipment used in the Kjeldahl method for nitrogen determination and protein estimation in different types of samples.
Digestion converts nitrogen present in the sample into an ammonium form using suitable reagents and heating. The distillation stage is then used as part of the subsequent nitrogen determination process.
Yes. Standard Kjeldahl digestion units are available in 3-test and 6-test configurations, allowing laboratories to select a model according to their sample testing requirements.
The standard models support 300 ml and 500 ml flasks. Micro Kjeldahl configurations are available with smaller flask capacities such as 30 ml, 50 ml and 100 ml.
The listed Kjeldahl digestion unit models have a maximum temperature specification of 350°C. Individual energy regulators are provided for heating control.
A Micro Kjeldahl unit is intended for laboratory applications requiring nitrogen determination and protein estimation with smaller sample volumes.
Kjeldahl units are used in food and dairy testing, fertilizer and agricultural testing, chemical and pharmaceutical laboratories, environmental testing, research institutions and quality control laboratories.
Model selection should consider the number of test positions, required flask capacity, heating configuration, sample volume, construction and optional accessories required for the laboratory application.