Trade Mark No.: 2022609

Class B Dental Autoclave Manufacturer in India

Bionics Scientific is a Class B dental autoclave manufacturer in India, offering 16, 18 and 23 litre front-loading steam sterilizers for dental clinics, hospitals, veterinary clinics and medical facilities. These dental autoclaves use pre-vacuum air removal, saturated steam sterilization and post-vacuum drying for compatible wrapped, unwrapped, solid, porous and hollow instruments.

The available models operate at 121°C and 134°C and combine programmable cycles with a stainless steel chamber, digital controls, independent pressure monitoring and a double-locking safety system. Bowie-Dick, Helix and vacuum test programs help operators routinely check air removal, steam penetration and vacuum performance according to their facility procedures.

Our Class B sterilizers are designed with reference to EN 13060 requirements for small steam sterilizers. Buyers should confirm the certification, validation documents and configuration supplied with the selected model before ordering.

Class B Dental Autoclave Models: 16L, 18L and 23L

Three chamber capacities help dental practices select a machine according to daily patient volume, instrument turnaround and available installation space. The 16 litre model suits lower instrument loads, while the 18 and 23 litre models provide additional capacity for growing or multi-chair clinics. Final selection should be based on the dimensions and packaging instructions of the instruments being processed.

Features:

Adopts European Class B standard Excellent vacuum dry effect
Automatic water filling option Built-in steam generator
High quality stainless steel chamber Meets European Standard EN 13060
User-friendly operation Digital control panel
Descriptive indicators and alarms Independent pressure gauge
Built-in printer PC connection interface
Overheat protection Double-locking safety system

Class B Sterilizer Specifications:

Model BST/DA-16 BST/DA-18 BST/DA-23
Sterilization Class European Class B standard Dental Autoclave
Capacity 16 liters 18 liters 23 litres
Sterilizing temperature 121°C, 134°C
Sterilization applications Compatible wrapped, unwrapped, solid, porous and hollow instruments
Dry procedure Vacuum drying
Display LED screen
Test program Bowie & Dick test, Helix test, Vacuum test
Safety Features Safety valve, double-control locking system and self-test alarm
Water supply system Two water tanks inside
Capacity of water tank 3.5 litre clean-water tank and 5 litre waste-water tank
Instrument container 5-layer tray rack with 3 trays
Voltage 220V±10%, 50Hz
Optional Accessories -Print by optional external mini-printer or download from USB port ( Sterilizing data)
-Extra stainless steel trays

Programs:

Program Temperature Pressure (bar) Holding Time (min) Total Cycle Time (min)
SOLID 134°C 2.1 4 18-30
SOLID 121°C 1.1 20 30-45
WRAPPED 134°C 2.1 6 30-40
WRAPPED 121°C 1.1 20 35-50
TEXTILE 134°C 2.1 10 45-65
TEXTILE 121°C 1.1 30 50-75
PRION 134°C 2.1 18 45-70
PLASTIC 105°C 0.2 30 50-65
B&D TEST 134°C 2.1 3.5 22-35
VACUUM TEST ------ ----- 3.5 4-10

Applications of Class B Dental Autoclaves

  • Dental Clinics
  • Hospitals
  • Veterinary Clinics
  • Medical Colleges
  • Research Laboratories

How a Class B Dental Autoclave Works

A Class B cycle first removes air from the chamber and instrument load through vacuum pulses. Saturated steam then contacts the load at the selected temperature for the programmed holding time. After exposure, post-vacuum drying removes residual moisture before the cycle is completed. The four essential steam-sterilization parameters are steam, pressure, temperature and time.

Dental Autoclave Testing and Cycle Monitoring

Routine monitoring helps a clinic confirm that the sterilizer is operating as intended. The available test programs include:

  • Vacuum test: checks chamber tightness and vacuum performance.
  • Bowie-Dick test: checks air removal and steam penetration in a pre-vacuum sterilizer.
  • Helix test: challenges steam penetration into hollow instruments.
  • Cycle records: an optional printer or USB connection can retain sterilization data.

Mechanical, chemical and biological monitoring should be performed according to the manufacturer’s instructions and the clinic’s applicable infection-control requirements. For independent technical guidance, see the CDC guidance on steam sterilization.

How to Choose a Dental Autoclave for Your Clinic

  • Chamber capacity: compare 16, 18 and 23 litre models with the number of instrument sets processed each day.
  • Instrument type: confirm that the selected cycle is suitable for solid, porous, hollow or wrapped loads.
  • Testing: check whether Bowie-Dick, Helix and vacuum test programs are required by your workflow.
  • Traceability: select printer or USB data recording when cycle documentation is required.
  • Utilities and space: verify electrical supply, overall dimensions, ventilation and service access before installation.
  • Documentation: request the user manual, supplied certifications, validation documents and accessories with the quotation.

Request Dental Autoclave Price and Specifications

Tell us your preferred 16, 18 or 23 litre capacity and daily instrument load. Our sales team will share the suitable model specifications, available options and quotation.

Request Price & Brochure

Frequently Asked Questions

A Class B dental autoclave is an advanced steam sterilizer that uses a vacuum system to remove air before sterilization. It is suitable for sterilizing wrapped, hollow, and solid dental instruments.

A Class B autoclave uses pre-vacuum air removal to help steam reach compatible wrapped, porous and hollow dental instruments when the validated cycle and loading instructions are followed.

A dental autoclave sterilizes instruments by using high-pressure saturated steam at high temperatures to destroy bacteria, viruses, fungi, and spores.

Class B autoclaves can sterilize dental handpieces, surgical instruments, mirrors, forceps, scalers, wrapped instruments, and hollow devices.

Cycle duration depends on the selected program, temperature and load. The listed Bionics models provide total cycle times from approximately 18 to 75 minutes.

Dental autoclaves typically operate at 121°C or 134°C, with 134°C being commonly used for rapid and effective sterilization.

Yes, a Class B dental autoclave is specifically designed to sterilize wrapped instruments, allowing them to remain sterile until use.

Testing and maintenance frequency should follow the manufacturer’s instructions, applicable regulations and the clinic’s infection-control protocol.

Common causes include overloading the chamber, improper instrument arrangement, insufficient water, blocked filters, or damaged door seals.

The ideal size depends on patient volume and instrument load. An 18-litre or 23-litre Class B autoclave is suitable for most dental clinics and hospitals.

Dental Autoclave Manufacturers and Suppliers in India

Bionics Scientific supplies Class B dental autoclaves for dental clinics, hospitals, medical colleges, veterinary facilities and research laboratories across India. Models are available in 16, 18 and 23 litre capacities for different instrument loads and daily sterilization requirements.

For model selection, technical specifications, available documentation and dental autoclave prices, contact our sales team. We can help you compare the available chamber capacities and select a suitable configuration.

Explore Related Autoclave Sterilizers

Class B dental autoclave sterilizer for dental clinics

Submit Your Request

To know more about our products, Please fill this enquiry form

Need more information

Connect with us for your business enquiries. Generally, we respond within a day.

Call Us

+91 9111161955 | 9376651333

Email us

info@bionicsscientific.com