Portable Conductivity and TDS Meter – Handheld BST-CT56 and Table Top BST-CT57

Portable Conductivity and TDS Meter for Lab, Industry and Field

Quick answer: a conductivity and TDS meter measures how well a liquid carries electric current and the amount of dissolved solids in it. We make two models: the handheld BST-CT56 and the portable / table top BST-CT57. Both have a large LCD, single or multi point calibration with up to 5 points, a data hold function and a USB interface. The BST-CT57 has the wider range, up to 500 mS/cm, and stores 10,000 data points.

Conductivity and TDS meters are used in laboratories, industry and field work. Ours are microprocessor-controlled and show readings on a large LCD. You can choose between a handheld unit and a portable / table top unit, depending on where you will use it and how much data you need to store.

Price depends on the model and quantity and is shared on enquiry. Get conductivity and TDS meter price and specifications. If you also measure pH, see our portable pH meter, or browse all our laboratory meters.

Key Features of Our Conductivity and TDS Meter

  • Conductivity and TDS in one meter.
  • Handheld and portable / table top models.
  • Microprocessor-controlled measurement functions.
  • Large LCD display for clear readings.
  • Data hold function: freezes the displayed reading so you can record it.
  • Auto power-off function when the meter is not in use.
  • Single and multi point calibration: up to 5 points. The calibration type differs by model.
  • USB interface and data storage on both models.
  • Carrying case: optional on the BST-CT56.
  • Suitable for laboratory and research applications.

Conductivity and TDS Meter Specifications

ParameterBST-CT56BST-CT57
DesignHand heldPortable / table top
Keypad controlsPush buttonTouch screen
Data storage10010,000 data points
Conductivity range 0 to 19.99, 199.9, 1999 µS/cm;
19.99, 199.9 mS/cm
0.000 to 500 mS/cm in 4 ranges:
  • Up to 200 µS/cm
  • 200.0 µS/cm to 2.000 mS/cm
  • 2.000 mS/cm to 20.00 mS/cm
  • 20.00 mS/cm to 500.0 mS/cm
TDS range 0 to 9.99, 99.9, 999 ppm;
9.99, 99.9 ppt
0.0 to 500.0 ppt in 4 ranges:
  • Up to 200.0 ppm
  • 200.0 to 2000 ppm
  • 2000 ppm to 20.00 ppt
  • 20.00 to 500.0 ppt
Temperature range-10.0 to 110.0 °C-5 to 105 °C
Resolution and accuracy0.05% full scale and ±1% full scale + 1 LSD0.05% full scale and ±1% full scale + 1 LSD
CalibrationUp to 5 points, single or multi pointUp to 5 points, single or multi point
Calibration typeAutomatic / manualAutomatic
Carrying caseOptionalNot listed
Power source4 AAA batteries (listed as 1.4 V each) or 9 VDC power adapter220 V adapter
USB interfaceYesYes
Auto power offYesYes
Data hold functionYesYes
AccessoriesBatteries, power adapter, electrode stand, electrode holder, wash bottle, calibrating standards, a dust protective cover and an instruction manual.

Please confirm with our team which accessories come with each model, and the TDS conversion setting, before ordering.

What the Specifications Mean

Conductivity and TDS are related but not the same. Conductivity tells you how well the liquid carries current, in µS/cm or mS/cm (1 mS/cm is 1000 µS/cm). TDS is the amount of dissolved solids, in ppm or ppt. A meter works out TDS from the conductivity reading, so it is an estimate, and the result depends on the conversion factor used.

The accuracy figure is tied to the range. "±1% of full scale" means the possible error grows with the range you are on. On a range that ends at 200 µS/cm, 1% of full scale is 2 µS/cm. So pick a meter whose ranges suit the samples you actually measure.

Calibration points are the number of standard solutions you use when you calibrate. Both models accept up to 5 points, and you can calibrate with a single point or with several.

How to Choose Between BST-CT56 and BST-CT57

Choose the BST-CT56 if you want a handheld meter you can carry to the sample. It runs on 4 AAA batteries or a 9 VDC adapter, uses push buttons, stores 100 readings and offers both automatic and manual calibration. A carrying case is available as an option. Its widest ranges go up to 199.9 mS/cm and 99.9 ppt.

Choose the BST-CT57 if you need a wider range or more stored data. It covers up to 500 mS/cm and 500.0 ppt, has a touch screen and stores 10,000 data points. Keep in mind that it runs from a 220 V adapter, so it needs mains power, and a carrying case is not listed for it.

If you are still unsure, tell us the samples you test, the range you expect and how many readings you log, and we will suggest a model.

Where Conductivity and TDS Meters Are Used

These meters are used in laboratory, research, industrial and field applications where you need to check conductivity or dissolved solids in a liquid. Water quality checks are a common example. If you make distilled water in your lab, our water distiller may also be of interest.

Why Choose Bionics Scientific?

Bionics Scientific has been making laboratory equipment for 26 years, and we operate as a unit of Kartal Projects Private Limited in Delhi. We supply across India and to overseas buyers. When you write to us, our team helps with model selection and price details.

Our Certifications

The certificates below are held by Kartal Projects Private Limited and issued by Euroglobe Registrars. Each one can be verified with Euroglobe Registrars using its certificate number.

CertificateCertificate no.ScopeValid until
ISO 9001:2015 Quality Management System184876Products as per annexure, which lists lab refrigerators and deep freezer30-03-2029
CE – Directive MDD 93/42/EEC184877Technical file; products as per annexure30-03-2029
GMP (Good Manufacturing Practices)184878Products as per annexure, which lists lab refrigerators and deep freezer30-03-2029
NSF/ANSI 61183884Manufacture and supply of bio-safety cabinet, laboratory equipment and scientific equipment08-03-2027

Certificate scope is as stated on each certificate. Please ask our team for the annexure and confirm whether it covers the meter model you plan to buy.

Looking for a Conductivity and TDS Meter?

Tell us the measurement range you need, your application and whether you want a handheld or table top unit. We will send product details, technical specifications and a quotation.

Request a Quote Call +91 9111161955

You can also call +91 9376651333, use the enquiry form on this page or email info@bionicsscientific.com.

Conductivity and TDS Meter FAQs

What is a conductivity and TDS meter?

It is an instrument that measures the electrical conductivity of a liquid and the amount of total dissolved solids in it.

What is the difference between conductivity and TDS?

Conductivity shows how well a liquid carries current and is given in µS/cm or mS/cm. TDS is the amount of dissolved solids, in ppm or ppt, and is worked out from the conductivity reading.

Which models do you offer?

The handheld BST-CT56 and the portable / table top BST-CT57.

What conductivity range does each model cover?

BST-CT56 covers 0 to 19.99, 199.9 and 1999 µS/cm, and 19.99 and 199.9 mS/cm. BST-CT57 covers 0.000 to 500 mS/cm in 4 ranges.

What TDS range does each model cover?

BST-CT56 covers 0 to 9.99, 99.9 and 999 ppm, and 9.99 and 99.9 ppt. BST-CT57 covers 0.0 to 500.0 ppt in 4 ranges.

How accurate is the meter?

Resolution is 0.05% of full scale and accuracy is ±1% of full scale + 1 LSD on both models.

How is the meter calibrated?

Both models accept up to 5 calibration points, single or multi point. The BST-CT56 supports automatic or manual calibration, and the BST-CT57 uses automatic calibration.

How much data can it store?

100 readings on the BST-CT56 and 10,000 data points on the BST-CT57.

Portable Conductivity and TDS Meter

Submit Your Request

To know more about our products, Please fill this enquiry form

Or email us directly: info@bionicsscientific.com

Need more information

Connect with us for your business enquiries. Generally, we respond within a day.

Call Us

+91 9111161955 | 9376651333

Email us

info@bionicsscientific.com