Bionics Scientific is a laboratory fume hood manufacturer in India, offering fume hood systems for chemical handling, research and laboratory applications. Our laboratory fume hoods are available in standard sizes of 4 ft, 5 ft, 6 ft, 7 ft and 8 ft, with customized configurations based on laboratory requirements. Options include epoxy powder-coated mild steel and stainless steel construction, along with vertical or optional horizontal sash arrangements.
Often known as a chemical fume hood, this equipment is designed to help control hazardous fumes and vapours generated during laboratory work. Bionics Scientific also manufactures a range of laboratory and cleanroom equipment for research, pharmaceutical, testing and industrial laboratory applications.
| Durable and chemical-resistant construction | High performance centrifugal blower |
| Powder Coated Mild Steel / Stainless Steel MOC | Efficient Exhaust Airflow System |
| Double wall construction | Easy to clean surfaces |
| Vertical or horizontal sliding sash | Efficient fluorescent lighting |
| Energy saving blowers | Customizable Model Configurations |
Bionics Scientific manufactures and supplies laboratory fume hoods for pharmaceutical, chemical, educational, research and industrial laboratories. Our range includes standard 4 ft, 5 ft, 6 ft, 7 ft and 8 ft models, along with customized options based on the required working dimensions and application. Customers can choose suitable construction materials, sash configurations and optional airflow monitoring features according to their laboratory needs.
Construction: Laboratory fume hoods are available with double-wall construction using epoxy powder-coated mild steel or stainless steel, depending on the selected configuration. The inner walls and baffles are designed to support suitable airflow within the working area. Construction materials and internal lining options can be selected according to the laboratory application and model specifications.
Sashes: Standard fume hood models are generally equipped with vertical sliding sashes. Horizontal sash configurations can also be provided, depending on the selected model. The sash moves along stainless steel guides, and tempered safety glass is used as specified for the model.
Controls: Our fume hoods are equipped with easy to use controls which are fixed outside the working area in order to provide convenient working environment. These fume hoods have start / stop switches for whole the unit and a light on / off switch.
Lighting: Our fume hoods are Supplied with fluorescent bulb shielded from the hood interior by laminated safety glass or tempered glass panel. The bulb is operated by a on / off switch and bulb changing process is done from the hood exterior without major disassembly of the unit.
Alarm: Selected fume hood configurations can include an audio-visual alarm system to alert operators when airflow conditions move outside the configured limits. Depending on the model, airflow monitoring sensors and remote monitoring connections may also be available. Ducted and ductless configurations should be confirmed according to the selected model and application.
A laboratory fume hood draws room air through the front sash opening and across the enclosed work area. During laboratory procedures, fumes and vapours generated inside the hood are carried toward the exhaust system, helping reduce operator exposure under the intended operating conditions. Proper airflow, sash position and laboratory ventilation are important for effective operation.
For general guidance on laboratory chemical safety and engineering controls, refer to the OSHA Laboratory Standard .
| Model.No | BST/FH-422 | BST/FH-522 | BST/FH-622 | BST/FH-733 | BST/FH-833 |
|---|---|---|---|---|---|
| Working Size (ft.) | 4' x 2' x 2' | 5' x 2' x 2' | 6' x 2' x 2' | 7' x 3' x 3' | 8' x 3' x 3' |
| MOC | CRCA 18G Epoxy Powder Coated | ||||
| Stand | M.S Pipe (18G) Powder coated | ||||
| Working Table Top | M.S Powder Coated Sheet Covered with P.P Sheet | ||||
| Exhaust System | Motor Blower Assembly Covered with G.I Sheet | ||||
| Door / Sash | Door vertical Folding Type. | ||||
| Air Velocity | ≥0.5m/s | ||||
| Noise Level | 65dBA | ||||
| Glass Window | Two layer toughen glass, 5mm thickness, Motor Control, height adjustable | ||||
| Make-up Air | Air needed to replace the air exhausted from a room by the fume hood and other ventilation devices. | ||||
| Face Velocity | Air velocity measured across the open sash area. The specified face velocity should be confirmed for the selected model and operating condition. | ||||
| Electrical Fittings | Electrical Sockets & MCB Switch | ||||
| Illumination | Fluorescent Lamp or UV Lamp | ||||
| Optional |
- HEPA Filter - Caster wheels - Horizontal sash - SS 304 / SS 316 MOC - Temperature indicator - Face Velocity Meter - Airflow Indicator - Audio / Visual alarm |
||||
| Power source | 220 / 230 Volts | ||||
| Air Foil Fume Hood | Flat Front Fume Hood | Thin Wall Fume Hood |
| Walk-In Fume Hood | Demonstration Fume Hood | Double-Sided Fume Hood |
| Perchloric Fume Hood | Radio Isotope Fume Hood | Benchtop Fume Hood |
Laboratory fume hoods are used in facilities where chemical fumes, vapours or gases may be generated during laboratory procedures. Typical applications include:
For laboratories requiring biological containment or clean-air work areas, Bionics Scientific also offers Class II Biosafety Cabinets and Laminar Air Flow Cabinets .
Bionics Scientific manufactures laboratory fume hoods in multiple standard sizes and customized configurations to suit different laboratory requirements. Customers can select construction materials, working dimensions, sash configurations and optional monitoring features according to their application.
Share your required size, construction material, application and installation requirements with our team. We can help you select a suitable standard or customized laboratory fume hood configuration.
Request a Quote