Laboratory Fume Hood Manufacturer in India

Laboratory Fume Hood for Safe Chemical Handling

Laboratory Fume Hood Stations by Bionics Scientific are available in various sizes and dimensions to meet specific requirements of your research. These fume hoods have a choice of vertical or horizontal sliding sash and MS or stainless steel construction. The standard sizes of our fume hoods are available in most demanded requirements (4ft, 5 ft, 6 ft & 8 ft).

Often known as a chemical fume hood, this equipment is designed to help control hazardous fumes and vapours generated during laboratory work. Bionics Scientific also manufactures a range of laboratory and cleanroom equipment for research, pharmaceutical, testing and industrial laboratory applications.

Fume Hood Features

Durable and chemical-resistant construction High performance centrifugal blower
Powder Coated Mild Steel / Stainless Steel MOC Efficient Exhaust Airflow System
Double wall construction Easy to clean surfaces
Vertical or horizontal sliding sash Efficient fluorescent lighting
Energy saving blowers CE & ISO certified

Laboratory Fume Hood Manufacturer in India

Bionics Scientific is a Delhi based India’s one of the leading fume hood manufacturers and suppliers in India . Our Chemical or laboratory fume hoods are CE & ISO certified. The standard size of our products are 4ft, 5 ft, 6 ft, 7ft and 8 ft. We also manufacture customized fume hood as per modern laboratory requirement. Out units is most energy efficient and safe in today’s market. Our units are user friendly and designed to fulfill the requirements of new generation scientist. The stainless steel construction promise low vibration, solid installation and less noise.

Construction: Our fume hoods come with double wall construction made of Epoxy Coated Mild Steel or Stainless Steel as required by customer. It is ensured that the exterior is matched with the base unit. The inner walls and baffles are made of molded reinforced thermoset epoxy resins that meet or exceed NFPA 45 standard on Fire protection for laboratories using chemicals. The jambs are radiuses and aerodynamically designed to reduce the turbulence as the air enters the hood. The construction materials of our fume hoods are used as mild steel, type 304 or 316 stainless steel (Epoxy Coated).

Sashes: Our standard models of fume hoods are generally equipped with vertical sashes but as required horizontal sashes can be fixed. The sliding sash of fume hoods rides in 18 gage type 316 stainless steel stainless steel sash guides. Tempered safety glass is used as standard.

Controls: Our fume hoods are equipped with easy to use controls which are fixed outside the working area in order to provide convenient working environment. These fume hoods have start / stop switches for whole the unit and a light on / off switch.

Lighting: Our fume hoods are Supplied with fluorescent bulb shielded from the hood interior by laminated safety glass or tempered glass panel. The bulb is operated by a on / off switch and bulb changing process is done from the hood exterior without major disassembly of the unit.

Alarm: Our fume hoods are equipped with highly reliable audio / visual alarm device capable enough of detecting a drop or rise in airflow (no static pressure) through the hood unit. If the fume hood exhausts volume falls below a preset exhaust level, the alarm will alert the operator by sound and visual sign. The monitor also uses dual theristor or dual diode sensing system to measure the velocity. The sensor in fume hoods is mounted in a flow tube placed on either side wall or front face of the fume hood. Local Audible and visual alarms have capabilities for remote monitoring hook up. These fume hoods are designed in both ducted and ductless pattern.

How Does a Laboratory Fume Hood Work?

A laboratory fume hood draws room air through the front sash opening and across the enclosed work area. During laboratory procedures, fumes and vapours generated inside the hood are carried toward the exhaust system, helping reduce operator exposure under the intended operating conditions. Proper airflow, sash position and laboratory ventilation are important for effective operation.

For general guidance on laboratory chemical safety and engineering controls, refer to the OSHA Laboratory Standard .

Fume Hood Specifications

Model.No BST/FH-422 BST/FH-522 BST/FH-622 BST/FH-733 BST/FH-833
Working Size (ft.) 4' x 2' x 2' 5' x 2' x 2' 6' x 2' x 2' 7' x 3' x 3' 8' x 3' x 3'
MOC CRCA 18G Epoxy Powder Coated
Stand M.S Pipe (18G) Powder coated
Working Table Top M.S Powder Coated Sheet Covered with P.P Sheet
Exhaust System Motor Blower Assembly Covered with G.I Sheet
Door / Sash Door vertical Folding Type.
Air Velocity ≥0.5m/s
Noise Level 65dBA
Glass Window Two layer toughen glass, 5mm thickness, Motor Control, height adjustable
Make-up Air Air needed to replace the air exhausted from a room by the fume hood and other ventilation devices.
Face Velocity The velocity of the air passing through the work opening of the fume hood measured in the plane of the sash. Measured in feet per minute (fpm), or liters per minute.
Electrical Fittings Electrical Sockets & MCB Switch
Illumination Fluorescent Lamp or UV Lamp
Optional - HEPA Filter
- Caster wheels
- Horizontal sash
- SS 304 / SS 316 MOC
- Temperature indicator
- Face Velocity Meter
- Airflow Indicator
- Audio / Visual alarm
Power source 220 / 230 Volts

Types of Laboratory Fume Hoods

Air Foil Fume Hood Flat Front Fume Hood Thin Wall Fume Hood
Walk-In Fume Hood Demonstration Fume Hood Double-Sided Fume Hood
Perchloric Fume Hood Radio Isotope Fume Hood Benchtop Fume Hood

Applications of Laboratory Fume Hoods

Laboratory fume hoods are used in facilities where chemical fumes, vapours or gases may be generated during laboratory procedures. Typical applications include:

  • Chemical testing laboratories
  • Pharmaceutical research and quality-control laboratories
  • Research and development laboratories
  • Educational and university laboratories
  • Industrial testing laboratories
  • Analytical laboratories

For laboratories requiring biological containment or clean-air work areas, Bionics Scientific also offers Class II Biosafety Cabinets and Laminar Air Flow Cabinets .

Why Choose Bionics Scientific for Laboratory Fume Hoods?

Bionics Scientific manufactures laboratory fume hoods in multiple standard sizes and customized configurations to suit different laboratory requirements. Customers can select construction materials, working dimensions, sash configurations and optional monitoring features according to their application.

  • Standard and customized fume hood configurations
  • 4 ft, 5 ft, 6 ft, 7 ft and 8 ft size options
  • Epoxy powder-coated mild steel construction
  • SS 304 and SS 316 construction options
  • Vertical and optional horizontal sash configurations
  • Airflow monitoring and audio-visual alarm options

Need a Laboratory Fume Hood for Your Lab?

Share your required size, construction material, application and installation requirements with our team. We can help you select a suitable standard or customized laboratory fume hood configuration.

Request a Quote

Related Products:

Laboratory fume hood manufactured by Bionics Scientific

Submit Your Request

To know more about our products, Please fill this enquiry form

Or email us directly: info@bionicsscientific.com

Need more information

Connect with us for your business enquiries. Generally, we respond within a day.

Call Us

+91 9111161955 | 9376651333

Email us

info@bionicsscientific.com